The interface is the defining element of non-invasive ventilation (NIV). Nowadays different types of interfaces, which differ in terms of shape, mechanical properties and comfort, are available, and their choice and fitting is a key element of NIV success. In the last decade, larger masks covering the entire face and specifically designed helmets have been developed for delivering NIV, theoretically improving comfort and patient tolerance. Recent studies have shown that, despite marked heterogeneity in mask internal volume and compliance, the dynamic dead space and, above all, the clinical efficacy of different masks is on average very similar. Thus, with the exception of the nasal mask and the mouthpiece, a variety of interfaces for NIV can be used in the acute care setting. However, prevention and monitoring of interfaces related side-effects and evaluation of patient tolerance are crucial to avoid NIV failure. To optimize effectiveness and costs, an interface strategy for NIV in acute respiratory failure could be convenient in clinical practice.

Recent advances in interfaces for non-invasive ventilation : from bench studies to practical issues / G.F. Sferrazza Papa, F. Di Marco, E. Akoumianaki, L. Brochard. - In: MINERVA ANESTESIOLOGICA. - ISSN 0375-9393. - 78:10(2012 Oct), pp. 1146-1153.

Recent advances in interfaces for non-invasive ventilation : from bench studies to practical issues

G.F. Sferrazza Papa
Primo
;
F. Di Marco
Secondo
;
2012

Abstract

The interface is the defining element of non-invasive ventilation (NIV). Nowadays different types of interfaces, which differ in terms of shape, mechanical properties and comfort, are available, and their choice and fitting is a key element of NIV success. In the last decade, larger masks covering the entire face and specifically designed helmets have been developed for delivering NIV, theoretically improving comfort and patient tolerance. Recent studies have shown that, despite marked heterogeneity in mask internal volume and compliance, the dynamic dead space and, above all, the clinical efficacy of different masks is on average very similar. Thus, with the exception of the nasal mask and the mouthpiece, a variety of interfaces for NIV can be used in the acute care setting. However, prevention and monitoring of interfaces related side-effects and evaluation of patient tolerance are crucial to avoid NIV failure. To optimize effectiveness and costs, an interface strategy for NIV in acute respiratory failure could be convenient in clinical practice.
Settore MED/10 - Malattie dell'Apparato Respiratorio
ott-2012
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/209171
Citazioni
  • ???jsp.display-item.citation.pmc??? 18
  • Scopus 47
  • ???jsp.display-item.citation.isi??? 38
social impact