The effect of a progressively increasing work rate (15 W X min-1) up to exhaustion on the time course of O2 uptake (VO2), ventilation (VE) and heart rate (HR) has been studied in weight lifters (WL) in comparison to endurance cyclists (Cycl) and sedentary controls (Sed). VO2 and VE were measured as average value of 30-s intervals by a semiautomatic open circuit method. VO2max was 2.55 +/- 0.33; 4.29 +/- 0.53 and 2.86 +/- 0.19 l X min-1 in WL, Cycl and Sed respectively. With time and work rate, while VO2 and HR increased linearly, VE changed its slope at two levels. The 1st VE change occurred at a work load corresponding to a mean (+/- SD) VO2 of 1.50 +/- 0.26; 1.93 +/- 0.34; and 1.23 +/- 0.14 l X min-1 in WL, Cycl, and Sed respectively. VO2 values corresponding to the second VE change of slope were 2.18 +/- 0.32 in WL; 3.48 +/- 0.53 in Cycl and 2.17 +/- 0.28 l X min-1 in Sed. The first change of slope might be the consequence of the different readjustment of VO2 on-response and hence of early lactate in the different subjects. The second change seems to be comparable to the conventional anaerobic threshold and is achieved in all subjects when VE vs time slope is 7-10 l X min-1/min of exercise.

Ventilatory response during incremental exercise tests in weight lifters and endurance cyclists / A. Veicsteinas, P. Feroldi, A. Dotti. - In: EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY. - ISSN 0301-5548. - 53:4(1985), pp. 322-329.

Ventilatory response during incremental exercise tests in weight lifters and endurance cyclists

A. Veicsteinas
Primo
;
1985

Abstract

The effect of a progressively increasing work rate (15 W X min-1) up to exhaustion on the time course of O2 uptake (VO2), ventilation (VE) and heart rate (HR) has been studied in weight lifters (WL) in comparison to endurance cyclists (Cycl) and sedentary controls (Sed). VO2 and VE were measured as average value of 30-s intervals by a semiautomatic open circuit method. VO2max was 2.55 +/- 0.33; 4.29 +/- 0.53 and 2.86 +/- 0.19 l X min-1 in WL, Cycl and Sed respectively. With time and work rate, while VO2 and HR increased linearly, VE changed its slope at two levels. The 1st VE change occurred at a work load corresponding to a mean (+/- SD) VO2 of 1.50 +/- 0.26; 1.93 +/- 0.34; and 1.23 +/- 0.14 l X min-1 in WL, Cycl, and Sed respectively. VO2 values corresponding to the second VE change of slope were 2.18 +/- 0.32 in WL; 3.48 +/- 0.53 in Cycl and 2.17 +/- 0.28 l X min-1 in Sed. The first change of slope might be the consequence of the different readjustment of VO2 on-response and hence of early lactate in the different subjects. The second change seems to be comparable to the conventional anaerobic threshold and is achieved in all subjects when VE vs time slope is 7-10 l X min-1/min of exercise.
Anaerobic threshold; Cyclist; Heart rate; Incremental exercise test; Oxygen consumption; Ventilation; Weight lifter
Settore BIO/09 - Fisiologia
1985
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/207587
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 5
social impact