Within-individual biological variation of INR (CVB) was assessed in 245 selected stable warfarin-treated patients monitored by three thrombosis centers. Selection criteria were: treatment period of six months or longer before the observation period; at least six consecutive INRs within the therapeutic range of 2.0 - 3.0; interval between consecutive INR measurements of two weeks or longer; no change in warfarin dose; no changes in the patient's circumstances which may influence the INR, such as intercurrent diseases, invasive procedures, starting or stopping drugs interacting with warfarin. The minimum, maximum and mean within-individual coefficient of variation CVB of the INR measurements in the 245 selected patients were 0.4%, 14.5%, and 9.0%, respectively Analytical performance goals for the INR measurement (imprecision) could be derived from the mean CVB. For a therapeutic range of 2.0 - 3.0 with warfarin, the desirable and optimum imprecision of INR determination is <4.5% CV and <2.25% CV, respectively. The biological variation and analytical performance goals have been derived using classic laboratory methods but should be applicable to point-of-care testing as well.

Biological variation of INR in stable patients on long-term anticoagulation with warfarin / A.M. van den Besselaar, P. Fogar, V. Pengo, G. Palareti, S. Braham, M. Moia, A. Tripodi. - In: THROMBOSIS RESEARCH. - ISSN 0049-3848. - 130:3(2012 Sep), pp. 535-537. [10.1016/j.thromres.2012.05.028]

Biological variation of INR in stable patients on long-term anticoagulation with warfarin

S. Braham;A. Tripodi
2012

Abstract

Within-individual biological variation of INR (CVB) was assessed in 245 selected stable warfarin-treated patients monitored by three thrombosis centers. Selection criteria were: treatment period of six months or longer before the observation period; at least six consecutive INRs within the therapeutic range of 2.0 - 3.0; interval between consecutive INR measurements of two weeks or longer; no change in warfarin dose; no changes in the patient's circumstances which may influence the INR, such as intercurrent diseases, invasive procedures, starting or stopping drugs interacting with warfarin. The minimum, maximum and mean within-individual coefficient of variation CVB of the INR measurements in the 245 selected patients were 0.4%, 14.5%, and 9.0%, respectively Analytical performance goals for the INR measurement (imprecision) could be derived from the mean CVB. For a therapeutic range of 2.0 - 3.0 with warfarin, the desirable and optimum imprecision of INR determination is <4.5% CV and <2.25% CV, respectively. The biological variation and analytical performance goals have been derived using classic laboratory methods but should be applicable to point-of-care testing as well.
analytical performance goals; biological variation; International Normalized Ratio; prothrombin time; warfarin
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
Settore MED/09 - Medicina Interna
Settore MED/15 - Malattie del Sangue
set-2012
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/206297
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 10
social impact