Due to the limited distensibility of the everolimus-eluting bioresorbable vascular scaffold (ABSORB) compared to metallic platform stents, quantitative coronary arteriography (QCA) is a mandatory requirement for ABSORB deployment in the on-going ABSORB EXTEND Single-Arm Study. Visual assessment of vessel size in the ABSORB Cohort B study often lead to under and over-sizing of the 3 mm ABSORB in coronary vessels (recommended range of the vessel diameter ≥ 2.5 mm and ≤ 3.3 mm), with an increased risk of spontaneous incomplete scaffold apposition post ABSORB deployment. We report whether mandatory QCA assessment of vessel size pre-implantation, utilizing the maximal luminal diameter (Dmax) and established interpolated reference vessel diameter (RVD) measurements, has improved device/vessel sizing.

Proximal and distal maximal luminal diameters as a guide to appropriate deployment of the ABSORB everolimus-eluting bioresorbable vascular scaffold : a sub-study of the ABSORB Cohort B and the on-going ABSORB EXTEND Single Arm Study / V. Farooq, J. Gomez-Lara, S. Brugaletta, B. D. Gogas, H. M. Garcìa-Garcìa, Y. Onuma, R. J. van Geuns, A. Bartorelli, R. Whitbourn, A. Abizaid, P.W. Serruys. - In: CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS. - ISSN 1522-1946. - 79:6(2012 May 01), pp. 880-888. [10.1002/ccd.23177]

Proximal and distal maximal luminal diameters as a guide to appropriate deployment of the ABSORB everolimus-eluting bioresorbable vascular scaffold : a sub-study of the ABSORB Cohort B and the on-going ABSORB EXTEND Single Arm Study

A. Bartorelli;
2012

Abstract

Due to the limited distensibility of the everolimus-eluting bioresorbable vascular scaffold (ABSORB) compared to metallic platform stents, quantitative coronary arteriography (QCA) is a mandatory requirement for ABSORB deployment in the on-going ABSORB EXTEND Single-Arm Study. Visual assessment of vessel size in the ABSORB Cohort B study often lead to under and over-sizing of the 3 mm ABSORB in coronary vessels (recommended range of the vessel diameter ≥ 2.5 mm and ≤ 3.3 mm), with an increased risk of spontaneous incomplete scaffold apposition post ABSORB deployment. We report whether mandatory QCA assessment of vessel size pre-implantation, utilizing the maximal luminal diameter (Dmax) and established interpolated reference vessel diameter (RVD) measurements, has improved device/vessel sizing.
English
bioresorbable scaffold; coronary artery disease; maximal luminal diameter; quantitative coronary angiography
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
Articolo
Sì, ma tipo non specificato
1-mag-2012
79
6
880
888
Pubblicato
Periodico con rilevanza internazionale
Pubmed
info:eu-repo/semantics/article
Proximal and distal maximal luminal diameters as a guide to appropriate deployment of the ABSORB everolimus-eluting bioresorbable vascular scaffold : a sub-study of the ABSORB Cohort B and the on-going ABSORB EXTEND Single Arm Study / V. Farooq, J. Gomez-Lara, S. Brugaletta, B. D. Gogas, H. M. Garcìa-Garcìa, Y. Onuma, R. J. van Geuns, A. Bartorelli, R. Whitbourn, A. Abizaid, P.W. Serruys. - In: CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS. - ISSN 1522-1946. - 79:6(2012 May 01), pp. 880-888. [10.1002/ccd.23177]
none
Prodotti della ricerca::01 - Articolo su periodico
11
262
Article (author)
Periodico con Impact Factor
V. Farooq, J. Gomez Lara, S. Brugaletta, B.D. Gogas, H.M. Garcìa Garcìa, Y. Onuma, R.J. van Geuns, A. Bartorelli, R. Whitbourn, A. Abizaid, P.W. Serruys
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/205836
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 41
  • ???jsp.display-item.citation.isi??? 34
social impact