Background: Multidetector computed tomography (MDCT) is useful in evaluation of coronary artery bypass graft (CABG). However, radiation exposure is a reason for concern. We compared diagnostic performance and effective dose of a new dedicated post-processing reconstruction algorithm with BMI-adapted scanning protocol (MDCT-XTe) vs. standard prospective ECG-triggering protocol (MDCT-XT) and retrospective ECG-triggering (MDCT-Helical), compared to invasive coronary angiography (ICA), in the assessment of grafts and nongrafted or distal runoff coronary arteries. Methods: One hundred and nineteen patients with 277 grafts were randomized to Group 1 based on BMI-adapted scanning protocol with prospective ECG-triggering (40 patients), Group 2 with prospective ECG-triggering (39 patients) and Group 3 (40 patients) with retrospective ECG-triggering. Data were acquired using 64-slice MDCT. Results: MDCT correctly assessed the patency of all CABG in 3 groups. After comparison with ICA, MDCT was able to correctly detect the occlusion or stenosis of CABG in all groups, with the exception of one case of Group 3. In Group 3 sensitivity, specificity, positive predictive value, negative predictive value and accuracy of CABG evaluation were 100%, 98.4%, 96.7%, 100% and 98.9%, respectively. In Groups 1 and 2 the diagnostic accuracy of CABG evaluation was 100%. Effective radiation dose was 3.5 ± 1.4 mSv in Group 1 vs. 7.4 ± 2.6 mSv in Group 2 vs. 27.8 ± 9.4 mSv in Group 3. Conclusions: Our results indicated that MDCT-XTe and MDCT-XT have a diagnostic performance in the evaluation of CABG similar to MDCT-Helical, with a significant reduction of radiation exposure, specially for MDCT-XTe.

Diagnostic performance of two types of low radiation exposure protocol for prospective ECG-triggering multidetector computed tomography angiography in assessment of coronary artery bypass graft / D. Andreini, G. Pontone, S. Mushtaq, A. Annoni, A. Formenti, E. Bertella, A. Parolari, P. Agostoni, A. Bartorelli, G. Ballerini, C. Fiorentini, M. Pepi. - In: INTERNATIONAL JOURNAL OF CARDIOLOGY. - ISSN 0167-5273. - 157:1(2012), pp. 63-69.

Diagnostic performance of two types of low radiation exposure protocol for prospective ECG-triggering multidetector computed tomography angiography in assessment of coronary artery bypass graft

D. Andreini;G. Pontone;S. Mushtaq;E. Bertella;A. Parolari;P. Agostoni;A. Bartorelli;C. Fiorentini;
2012

Abstract

Background: Multidetector computed tomography (MDCT) is useful in evaluation of coronary artery bypass graft (CABG). However, radiation exposure is a reason for concern. We compared diagnostic performance and effective dose of a new dedicated post-processing reconstruction algorithm with BMI-adapted scanning protocol (MDCT-XTe) vs. standard prospective ECG-triggering protocol (MDCT-XT) and retrospective ECG-triggering (MDCT-Helical), compared to invasive coronary angiography (ICA), in the assessment of grafts and nongrafted or distal runoff coronary arteries. Methods: One hundred and nineteen patients with 277 grafts were randomized to Group 1 based on BMI-adapted scanning protocol with prospective ECG-triggering (40 patients), Group 2 with prospective ECG-triggering (39 patients) and Group 3 (40 patients) with retrospective ECG-triggering. Data were acquired using 64-slice MDCT. Results: MDCT correctly assessed the patency of all CABG in 3 groups. After comparison with ICA, MDCT was able to correctly detect the occlusion or stenosis of CABG in all groups, with the exception of one case of Group 3. In Group 3 sensitivity, specificity, positive predictive value, negative predictive value and accuracy of CABG evaluation were 100%, 98.4%, 96.7%, 100% and 98.9%, respectively. In Groups 1 and 2 the diagnostic accuracy of CABG evaluation was 100%. Effective radiation dose was 3.5 ± 1.4 mSv in Group 1 vs. 7.4 ± 2.6 mSv in Group 2 vs. 27.8 ± 9.4 mSv in Group 3. Conclusions: Our results indicated that MDCT-XTe and MDCT-XT have a diagnostic performance in the evaluation of CABG similar to MDCT-Helical, with a significant reduction of radiation exposure, specially for MDCT-XTe.
No
English
Coronary artery bypass graft; Multidetector computed tomography; Radiation dose exposure
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
Articolo
Sì, ma tipo non specificato
2012
157
1
63
69
7
Pubblicato
Periodico con rilevanza internazionale
Pubmed
info:eu-repo/semantics/article
Diagnostic performance of two types of low radiation exposure protocol for prospective ECG-triggering multidetector computed tomography angiography in assessment of coronary artery bypass graft / D. Andreini, G. Pontone, S. Mushtaq, A. Annoni, A. Formenti, E. Bertella, A. Parolari, P. Agostoni, A. Bartorelli, G. Ballerini, C. Fiorentini, M. Pepi. - In: INTERNATIONAL JOURNAL OF CARDIOLOGY. - ISSN 0167-5273. - 157:1(2012), pp. 63-69.
none
Prodotti della ricerca::01 - Articolo su periodico
12
262
Article (author)
si
D. Andreini, G. Pontone, S. Mushtaq, A. Annoni, A. Formenti, E. Bertella, A. Parolari, P. Agostoni, A. Bartorelli, G. Ballerini, C. Fiorentini, M. Pepi
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/203510
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 20
social impact