Chest ultrasonography is a useful tool to assess extravascular lung water at bedside. In presence of interstitial-alveolar imbibition, vertical artifacts arising from the pleura are detected; these are called B-lines. Although a positive linear correlation between B-lines and extravascular lung water has been shown in symptomatic heart failure patients, the subclinical phase of pulmonary imbibition and the clearance of B-lines after rapid body fluid removal have been less investigated. The aim of this study was to assess if chest ultrasound could detect lung water imbibition and its variations induced by dialysis, an experimental model of controlled rapid fluid loss. Forty-one patients undergoing hemodialysis were studied. Total number of B-lines from ultrasound chest scanning and vena cava diameters were measured before and after treatment. Before dialysis, most of the patients presented ultrasound signs of pulmonary imbibition despite the absence of dyspnea; the number of B-lines was associated with the accumulated weight before treatment (p < 0.05) as well as with the residual weight after dialysis (p < 0.01); B-lines and end-inspiratory and end-expiratory vena cava diameters were also significantly reduced after dialysis. Moreover, B-lines reduction was significantly related to weight loss. Ultrasound performed at the bedside can detect lung water and intravascular overload and their reduction after dialysis in yet asymptomatic patients. These observations add further evidence regarding the use of lung ultrasound and inferior vena cava measurement in estimating volume overload and monitoring the response to therapy both in hemodialysis and congestive heart failure patients.

Lung ultrasonography for the assessment of rapid extravascular water variation : evidence from hemodialysis patients / M. Trezzi, D. Torzillo, E. Ceriani, G.M. Costantino, S. Caruso, P.T. Damavandi, A. Genderini, M. Cicardi, N. Montano, C. Cogliati. - In: INTERNAL AND EMERGENCY MEDICINE. - ISSN 1828-0447. - 8:5(2013 Aug), pp. 409-415.

Lung ultrasonography for the assessment of rapid extravascular water variation : evidence from hemodialysis patients

G.M. Costantino;M. Cicardi;N. Montano
Penultimo
;
C. Cogliati
2013

Abstract

Chest ultrasonography is a useful tool to assess extravascular lung water at bedside. In presence of interstitial-alveolar imbibition, vertical artifacts arising from the pleura are detected; these are called B-lines. Although a positive linear correlation between B-lines and extravascular lung water has been shown in symptomatic heart failure patients, the subclinical phase of pulmonary imbibition and the clearance of B-lines after rapid body fluid removal have been less investigated. The aim of this study was to assess if chest ultrasound could detect lung water imbibition and its variations induced by dialysis, an experimental model of controlled rapid fluid loss. Forty-one patients undergoing hemodialysis were studied. Total number of B-lines from ultrasound chest scanning and vena cava diameters were measured before and after treatment. Before dialysis, most of the patients presented ultrasound signs of pulmonary imbibition despite the absence of dyspnea; the number of B-lines was associated with the accumulated weight before treatment (p < 0.05) as well as with the residual weight after dialysis (p < 0.01); B-lines and end-inspiratory and end-expiratory vena cava diameters were also significantly reduced after dialysis. Moreover, B-lines reduction was significantly related to weight loss. Ultrasound performed at the bedside can detect lung water and intravascular overload and their reduction after dialysis in yet asymptomatic patients. These observations add further evidence regarding the use of lung ultrasound and inferior vena cava measurement in estimating volume overload and monitoring the response to therapy both in hemodialysis and congestive heart failure patients.
lung ultrasound; pulmonary edema; B-lines; heart failure; hemodialysis
Settore MED/09 - Medicina Interna
ago-2013
18-mag-2011
Article (author)
File in questo prodotto:
File Dimensione Formato  
art_10.1007_s11739-011-0625-4.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 269.04 kB
Formato Adobe PDF
269.04 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/202351
Citazioni
  • ???jsp.display-item.citation.pmc??? 33
  • Scopus 90
  • ???jsp.display-item.citation.isi??? 75
social impact