Background: We report a case of delayed endovascular correction of graft collapse occurred after emergent Thoracic Endovascular Aortic Repair (TEVAR) for traumatic aortic isthmus rupture.Case presentation: In 7 th post-operative day after emergent TEVAR for traumatic aortic isthmus rupture (Gore TAG ® 28-150), a partial collapse of the endoprosthesis at the descending tract occurred, with no signs of visceral ischemia. Considering patient's clinical conditions, the graft collapse wasn't treated at that time. When general conditions allowed reintervention, the patient refused any new treatment, so he was discharged.Four months later the patient complainted for severe gluteal and sural claudication, erectile disfunction and abdominal angina; endovascular correction was performed. At 18 months the graft was still patent.Discussion and Conclusion: Graft collapse after TEVAR is a rare event, which should be detected and treated as soon as possible. Delayed correction of this complication can be lethal due to the risk of visceral ischemia and limbs loss.
Delayed endovascular treatment of descending aorta stent graft collapse in a patient treated for post- traumatic aortic rupture: a case report / G. Nano, D. Mazzaccaro, G. Malacrida, M. Occhiuto, S. Stegher, D.G. Tealdi. - In: JOURNAL OF CARDIOTHORACIC SURGERY. - ISSN 1749-8090. - 24:6(2011). [10.1186/1749-8090-6-76]
Delayed endovascular treatment of descending aorta stent graft collapse in a patient treated for post- traumatic aortic rupture: a case report
G. NanoPrimo
;D. MazzaccaroSecondo
;S. StegherPenultimo
;D.G. TealdiUltimo
2011
Abstract
Background: We report a case of delayed endovascular correction of graft collapse occurred after emergent Thoracic Endovascular Aortic Repair (TEVAR) for traumatic aortic isthmus rupture.Case presentation: In 7 th post-operative day after emergent TEVAR for traumatic aortic isthmus rupture (Gore TAG ® 28-150), a partial collapse of the endoprosthesis at the descending tract occurred, with no signs of visceral ischemia. Considering patient's clinical conditions, the graft collapse wasn't treated at that time. When general conditions allowed reintervention, the patient refused any new treatment, so he was discharged.Four months later the patient complainted for severe gluteal and sural claudication, erectile disfunction and abdominal angina; endovascular correction was performed. At 18 months the graft was still patent.Discussion and Conclusion: Graft collapse after TEVAR is a rare event, which should be detected and treated as soon as possible. Delayed correction of this complication can be lethal due to the risk of visceral ischemia and limbs loss.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.