Bileaflet prostheses are low profile, central flow orifice devices that show excellent hemodynamic performance and low thrombogenicity. Five models are currently used for heart valve replacement. Comprehensive and comparative studies regarding valve characteristics and functioning are lacking, making the updating and the familiarization by physicians and cardiologists with these prostheses difficult. We describe the valve design characteristics and evaluate the cine-fluoroscopic appearance and functioning of 387 bileaflet prostheses that have been implanted in 367 consecutive patients. The valve types are St Jude Medical (n = 69), Edwards-Duromedics (n = 74), Carbomedics (n = 1290) Sorin Bicarbon (n = 88) and Jyros (n = 27). The prostheses' fluoroscopic appearance was evaluated through multiple radiographic views (Siemens-Elema equipment with C-arm); the prostheses' functional evaluation was performed by obtaining the "tilting disk projection" (ie, with the radiographic beam parallel to both the valve ring plane and the tilting axis of disks) to calculate opening, closing, and travel angles of the disks. This study shows that each of the five bileaflet valves has distinctive design characteristics. Fluoroscopy is an easy, readily available, and useful technique that correctly identifies the prosthesis type and properly evaluates its functioning in the majority of cases.

Valve design characteristics and cine-fluoroscopic appearance of five currently available bileaflet prosthetic heart valves / P. Montorsi, D. Cavoretto, A. Repossini, A.L. Bartorelli, M.D. Guazzi. - In: AMERICAN JOURNAL OF CARDIAC IMAGING. - ISSN 0887-7971. - 10:1(1996 Jan), pp. 29-41-41.

Valve design characteristics and cine-fluoroscopic appearance of five currently available bileaflet prosthetic heart valves

P. Montorsi
Primo
;
A.L. Bartorelli
Penultimo
;
1996

Abstract

Bileaflet prostheses are low profile, central flow orifice devices that show excellent hemodynamic performance and low thrombogenicity. Five models are currently used for heart valve replacement. Comprehensive and comparative studies regarding valve characteristics and functioning are lacking, making the updating and the familiarization by physicians and cardiologists with these prostheses difficult. We describe the valve design characteristics and evaluate the cine-fluoroscopic appearance and functioning of 387 bileaflet prostheses that have been implanted in 367 consecutive patients. The valve types are St Jude Medical (n = 69), Edwards-Duromedics (n = 74), Carbomedics (n = 1290) Sorin Bicarbon (n = 88) and Jyros (n = 27). The prostheses' fluoroscopic appearance was evaluated through multiple radiographic views (Siemens-Elema equipment with C-arm); the prostheses' functional evaluation was performed by obtaining the "tilting disk projection" (ie, with the radiographic beam parallel to both the valve ring plane and the tilting axis of disks) to calculate opening, closing, and travel angles of the disks. This study shows that each of the five bileaflet valves has distinctive design characteristics. Fluoroscopy is an easy, readily available, and useful technique that correctly identifies the prosthesis type and properly evaluates its functioning in the majority of cases.
Fluoroscopy; Postoperative Care; Humans; Heart Valve Prosthesis; Prosthesis Design; Cineradiography; Mitral Valve; Follow-Up Studies; Time Factors; Aortic Valve; Heart Valve Diseases
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
gen-1996
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/201540
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 39
  • ???jsp.display-item.citation.isi??? ND
social impact