The template bleeding time is still the screening test for defects of platelet function, although it is an invasive and poorly reproducible technique. The PFA-100 measures platelet function at high shear. Whole blood is aspirated through a capillary to an aperture of a membrane coated with platelet agonists. The system measures the time required to obtain occlusion of the aperture by a platelet plug (closure time). We measured the closure times in the PFA-100 system and the bleeding time in seven patients with δ-storage pool deficiency, 10 patients with 'primary secretion defect' (not due to abnormalities of platelet granules or the arachidonate pathway), and 40 controls. Measurements were repeated 1 and 4 hours after intravenous infusion of desmopressin in six δ-storage pool deficiency and eight primary secretion defect patients. Baseline bleeding time and closure times with the collagen/epinephrine cartridge were longer in δ-storage pool deficiency and primary secretion defect patients than in controls. In contrast, closure times with the collagen/adenosine diphosphate cartridge were normal in both δ-storage pool deficiency and primary secretion defect patients. Treatment with desmopressin increased the plasma von Willebrand Factor levels, shortened the prolonged bleeding time, shortened the closure times with the collagen/adenosine diphosphate cartridge, and normalized the closure times with the collagen/epinephrine cartridge. Therefore, the PFA-100 test may be a less invasive alternative to the bleeding time in the diagnosis and therapeutic monitoring of patients with platelet secretion defects. The collagen/epinephrine cartridge is more sensitive than the collagen/adenosine diphosphate cartridge to defects of platelet secretion. Copyright (C) 1999 Elsevier Science Ltd.
Evaluation of platelet function with the PFA-100 system in patients with congenital defects of platelet secretion / M. Cattaneo, A. Lecchi, B. Agati, R. Lombardi, M. Zighetti. - In: THROMBOSIS RESEARCH. - ISSN 0049-3848. - 96:3(1999), pp. 213-217.
Evaluation of platelet function with the PFA-100 system in patients with congenital defects of platelet secretion
M. CattaneoPrimo
;
1999
Abstract
The template bleeding time is still the screening test for defects of platelet function, although it is an invasive and poorly reproducible technique. The PFA-100 measures platelet function at high shear. Whole blood is aspirated through a capillary to an aperture of a membrane coated with platelet agonists. The system measures the time required to obtain occlusion of the aperture by a platelet plug (closure time). We measured the closure times in the PFA-100 system and the bleeding time in seven patients with δ-storage pool deficiency, 10 patients with 'primary secretion defect' (not due to abnormalities of platelet granules or the arachidonate pathway), and 40 controls. Measurements were repeated 1 and 4 hours after intravenous infusion of desmopressin in six δ-storage pool deficiency and eight primary secretion defect patients. Baseline bleeding time and closure times with the collagen/epinephrine cartridge were longer in δ-storage pool deficiency and primary secretion defect patients than in controls. In contrast, closure times with the collagen/adenosine diphosphate cartridge were normal in both δ-storage pool deficiency and primary secretion defect patients. Treatment with desmopressin increased the plasma von Willebrand Factor levels, shortened the prolonged bleeding time, shortened the closure times with the collagen/adenosine diphosphate cartridge, and normalized the closure times with the collagen/epinephrine cartridge. Therefore, the PFA-100 test may be a less invasive alternative to the bleeding time in the diagnosis and therapeutic monitoring of patients with platelet secretion defects. The collagen/epinephrine cartridge is more sensitive than the collagen/adenosine diphosphate cartridge to defects of platelet secretion. Copyright (C) 1999 Elsevier Science Ltd.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.