Accurate measurements of the Cosmic Microwave Background (CMB) anisotropy call for high precision and reliability of the in-flight calibration. For extended surveys the CMB dipole provides an excellent calibration source at frequencies lower than ~ 200 GHz; however poorly known foreground emissions, such as diffuse galactic components, complicate the signal and introduce a systematic error in the calibration. We show that introducing a weight function that takes into account the uncertainty in the a priori knowledge of the sky, allows us to substantially improve the calibration accuracy with respect to methods involving galactic latitude cuts. This new method is tested for PLANCK-LFI radiometers at 30 and 100 GHz. On short time scales (less than 1 day) the absolute calibration of each channel can be recovered with an overall 1-2% accuracy. We also consider the effect of CMB anisotropy itself on the calibration, and find that knowledge of the CMB pattern on large scales is needed to keep the short-time scale calibration accuracy within 1%.

Optimized in-flight absolute calibration for extended CMB surveys / B. Cappellini, D. Maino, G. Albetti, P. Platania, R. Paladini, A. Mennella, M. Bersanelli. - In: ASTRONOMY & ASTROPHYSICS. - ISSN 0004-6361. - 409:1(2003), pp. 375-385.

Optimized in-flight absolute calibration for extended CMB surveys

B. Cappellini
Primo
;
D. Maino
Secondo
;
A. Mennella
Penultimo
;
M. Bersanelli
Ultimo
2003

Abstract

Accurate measurements of the Cosmic Microwave Background (CMB) anisotropy call for high precision and reliability of the in-flight calibration. For extended surveys the CMB dipole provides an excellent calibration source at frequencies lower than ~ 200 GHz; however poorly known foreground emissions, such as diffuse galactic components, complicate the signal and introduce a systematic error in the calibration. We show that introducing a weight function that takes into account the uncertainty in the a priori knowledge of the sky, allows us to substantially improve the calibration accuracy with respect to methods involving galactic latitude cuts. This new method is tested for PLANCK-LFI radiometers at 30 and 100 GHz. On short time scales (less than 1 day) the absolute calibration of each channel can be recovered with an overall 1-2% accuracy. We also consider the effect of CMB anisotropy itself on the calibration, and find that knowledge of the CMB pattern on large scales is needed to keep the short-time scale calibration accuracy within 1%.
Cosmology: cosmic microwave background; Methods: data analysis
Settore FIS/05 - Astronomia e Astrofisica
2003
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/199017
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? 12
social impact