Recent studies found a difference in body composition determined by skinfold thickness measurements between breast-fed and formula-fed infants in the first year of life. We therefore investigated the body composition of 79 infants at 12 months measured by total body electrical conductivity (TOBEC) and compared with early feeding mode (breast-feeding for at least 6 months versus formula-feeding or breast-feeding or for ≤2 months). Lower weight, stature and cranial circumference were associated with breast-feeding when the variables were compared using an ANOVA model. The groups did not significantly differ in terms of fat-free mass, but body-fat mass was lower among breast-fed infants. Multiple regression analysis showed a significant correlation between body fat mass and duration of breast-feeding and lower amounts of body fat correlated with a longer period of breast-feeding.

Total body elecritcal conductivity derived measurement of the body composition of breast or formula-fed infants at 12 months / R. Bellù, M. T. Ortisi, C. Agostoni, E. Riva, M. Giovannini. - In: NUTRITION RESEARCH. - ISSN 0271-5317. - 17:1(1997 Jan), pp. 23-29. [10.1016/S0271-5317(96)00229-1]

Total body elecritcal conductivity derived measurement of the body composition of breast or formula-fed infants at 12 months

C. Agostoni;E. Riva
Penultimo
;
M. Giovannini
Ultimo
1997

Abstract

Recent studies found a difference in body composition determined by skinfold thickness measurements between breast-fed and formula-fed infants in the first year of life. We therefore investigated the body composition of 79 infants at 12 months measured by total body electrical conductivity (TOBEC) and compared with early feeding mode (breast-feeding for at least 6 months versus formula-feeding or breast-feeding or for ≤2 months). Lower weight, stature and cranial circumference were associated with breast-feeding when the variables were compared using an ANOVA model. The groups did not significantly differ in terms of fat-free mass, but body-fat mass was lower among breast-fed infants. Multiple regression analysis showed a significant correlation between body fat mass and duration of breast-feeding and lower amounts of body fat correlated with a longer period of breast-feeding.
English
Breast-feeding ; Formula-feeding ; Body composition
Settore MED/38 - Pediatria Generale e Specialistica
Articolo
Sì, ma tipo non specificato
gen-1997
17
1
23
29
Pubblicato
Periodico con rilevanza internazionale
CrossRef
info:eu-repo/semantics/article
Total body elecritcal conductivity derived measurement of the body composition of breast or formula-fed infants at 12 months / R. Bellù, M. T. Ortisi, C. Agostoni, E. Riva, M. Giovannini. - In: NUTRITION RESEARCH. - ISSN 0271-5317. - 17:1(1997 Jan), pp. 23-29. [10.1016/S0271-5317(96)00229-1]
none
Prodotti della ricerca::01 - Articolo su periodico
5
262
Article (author)
Periodico senza Impact Factor
R. Bellù, M.T. Ortisi, C. Agostoni, E. Riva, M. Giovannini
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/195549
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 7
social impact