In 14 spontaneously breathing anesthetized rabbits, we used cyanoacrylate to glue a hollow capsule, at end expiration or at end inspiration, to the peritoneal surface of the tendinous portion of the diaphragm. The capsule was connected to a pressure transducer and a pipette calibrated in microliters. We filled the system with fluid and measured flow into the diaphragmatic surface facing the capsule (Fcap, microliter/cm2), from liquid displacement in the pipette at different hydraulic pressures in the system (Pcap). Pleural liquid pressure was simultaneously measured in the supraphrenic region (Psup). Fcap was positively correlated to transdiaphragmatic pressure gradient (Psup-Pcap) and breathing frequency but was unaffected by protein concentration of capsular fluid. For a breathing frequency of 30 cycles/min and a Psup - Pcap = -2 cmH2O, Fcap was 0.54 microliter.min-1.cm-2 for capsules applied at end expiration and 10-fold greater for capsules applied at end inspiration. Data indicate that the diaphragmatic tendinous portion in rabbits is a draining site for peritoneal fluid and that the conductance of the draining pathways (lymphatic stomata) is related to diaphragmatic tension. In the intact rabbit the average peritoneal fluid drainage through the tendinous portion of the diaphragm (approximately 16 cm2) was estimated at 43 microliters/min.

Liquid drainage through the peritoneal diaphragmatic surface / G. Miserocchi, D. Negrini, S. Mukenge, P. Turconi, M. Del Fabbro. - In: JOURNAL OF APPLIED PHYSIOLOGY. - ISSN 8750-7587. - 66:4(1989 Apr), pp. 1579-1585.

Liquid drainage through the peritoneal diaphragmatic surface

M. Del Fabbro
Ultimo
1989

Abstract

In 14 spontaneously breathing anesthetized rabbits, we used cyanoacrylate to glue a hollow capsule, at end expiration or at end inspiration, to the peritoneal surface of the tendinous portion of the diaphragm. The capsule was connected to a pressure transducer and a pipette calibrated in microliters. We filled the system with fluid and measured flow into the diaphragmatic surface facing the capsule (Fcap, microliter/cm2), from liquid displacement in the pipette at different hydraulic pressures in the system (Pcap). Pleural liquid pressure was simultaneously measured in the supraphrenic region (Psup). Fcap was positively correlated to transdiaphragmatic pressure gradient (Psup-Pcap) and breathing frequency but was unaffected by protein concentration of capsular fluid. For a breathing frequency of 30 cycles/min and a Psup - Pcap = -2 cmH2O, Fcap was 0.54 microliter.min-1.cm-2 for capsules applied at end expiration and 10-fold greater for capsules applied at end inspiration. Data indicate that the diaphragmatic tendinous portion in rabbits is a draining site for peritoneal fluid and that the conductance of the draining pathways (lymphatic stomata) is related to diaphragmatic tension. In the intact rabbit the average peritoneal fluid drainage through the tendinous portion of the diaphragm (approximately 16 cm2) was estimated at 43 microliters/min.
Animals; Diaphragm; Ascitic Fluid; Absorption; Rabbits; Peritoneal Cavity
Settore BIO/09 - Fisiologia
apr-1989
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/193851
Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 36
  • ???jsp.display-item.citation.isi??? 44
social impact