Local cerebral blood flow was measured in the mouse by means of the [14C]iodoantipyrine method. This method has been previously used in the monkey, dog, cat, and rat, but its application to small mammals such as the mouse requires special attention to potential sources of error. The small size of the mouse brain requires special attention to the rapid removal and freezing of the brain to minimize effects of postmortem diffusion of tracer in the tissue. Because of the relatively low diameter/length ratios of the catheters needed for arterial sampling in small animals, substantial errors can occur in the determination of the time course of the [14C]iodoantipyrine concentration in the arterial blood unless corrections for lag time and dead space washout in the catheter are properly applied. Local cerebral blood flow was measured in seven awake mice with appropriate care to minimize these sources of error. The values were found to vary from 48 ml/100 g/min in the corpus callosum to 198 ml/100 g/min in the inferior colliculus. The results demonstrate that the [14C]iodoantipyrine method can be used to measure local cerebral blood flow in the mouse and that the values in that species are, in general, somewhat higher than those in the rat.

Measurement of local cerebral blood flow with [14C]iodoantipyrine in the mouse / T. M. Jay, G. Lucignani, A. M. Crane, J. Jehle, L. Sokoloff. - In: JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM. - ISSN 0271-678X. - 8:1(1988 Feb), pp. 121-9-129. [10.1038/jcbfm.1988.16]

Measurement of local cerebral blood flow with [14C]iodoantipyrine in the mouse

G. Lucignani
Secondo
;
1988

Abstract

Local cerebral blood flow was measured in the mouse by means of the [14C]iodoantipyrine method. This method has been previously used in the monkey, dog, cat, and rat, but its application to small mammals such as the mouse requires special attention to potential sources of error. The small size of the mouse brain requires special attention to the rapid removal and freezing of the brain to minimize effects of postmortem diffusion of tracer in the tissue. Because of the relatively low diameter/length ratios of the catheters needed for arterial sampling in small animals, substantial errors can occur in the determination of the time course of the [14C]iodoantipyrine concentration in the arterial blood unless corrections for lag time and dead space washout in the catheter are properly applied. Local cerebral blood flow was measured in seven awake mice with appropriate care to minimize these sources of error. The values were found to vary from 48 ml/100 g/min in the corpus callosum to 198 ml/100 g/min in the inferior colliculus. The results demonstrate that the [14C]iodoantipyrine method can be used to measure local cerebral blood flow in the mouse and that the values in that species are, in general, somewhat higher than those in the rat.
Animals; Catheterization; Carbon Radioisotopes; Antipyrine; Blood Flow Velocity; Mice, Inbred C57BL; Mice; Cerebrovascular Circulation; Male
Settore MED/36 - Diagnostica per Immagini e Radioterapia
feb-1988
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/191954
Citazioni
  • ???jsp.display-item.citation.pmc??? 25
  • Scopus 110
  • ???jsp.display-item.citation.isi??? ND
social impact