To our knowledge, the effects of humidity of inspired air on bronchial blood flow in humans are unknown. During total cardiopulmonary bypass, we measured systemic to pulmonary bronchial blood flow (Qbr[s-p]) which is the volume of blood accumulating into the left side of the heart in the absence of pulmonary and coronary flow. A cannula was introduced into the right upper pulmonary vein and advanced into the lowermost portion of the left side of the heart. From this cannula Qbr(s-p) was vented by gravity and measured. Inspired gas (10 L/min, endotracheal tube, 50 percent O2 + 50 percent N2O) relative humidity was less than 20 percent and greater than 85 percent in group A (n = 25) and in group B (n = 25), respectively. Mean (+/- SE) Qbr(s-p) was 40.7 +/- 0.06 ml/min or 1.32 +/- 0.12 ml/min (percent cardiac output) in group A and 21.7 +/- 1.8 ml/min or 0.68 +/- 0.06 ml/min in group B. These data indicate that under these conditions Qbr(s-p) is increased by dry gas lung inflation in humans.

Inspired gas relative humidity affects systemic to pulmonary bronchial blood flow in humans / P. Agostoni, V. Arena, E. Doria, G. Susini. - In: CHEST. - ISSN 0012-3692. - 97:6(1990 Jun), pp. 1377-80-1380.

Inspired gas relative humidity affects systemic to pulmonary bronchial blood flow in humans

P. Agostoni
Primo
;
1990

Abstract

To our knowledge, the effects of humidity of inspired air on bronchial blood flow in humans are unknown. During total cardiopulmonary bypass, we measured systemic to pulmonary bronchial blood flow (Qbr[s-p]) which is the volume of blood accumulating into the left side of the heart in the absence of pulmonary and coronary flow. A cannula was introduced into the right upper pulmonary vein and advanced into the lowermost portion of the left side of the heart. From this cannula Qbr(s-p) was vented by gravity and measured. Inspired gas (10 L/min, endotracheal tube, 50 percent O2 + 50 percent N2O) relative humidity was less than 20 percent and greater than 85 percent in group A (n = 25) and in group B (n = 25), respectively. Mean (+/- SE) Qbr(s-p) was 40.7 +/- 0.06 ml/min or 1.32 +/- 0.12 ml/min (percent cardiac output) in group A and 21.7 +/- 1.8 ml/min or 0.68 +/- 0.06 ml/min in group B. These data indicate that under these conditions Qbr(s-p) is increased by dry gas lung inflation in humans.
Humans; Cardiopulmonary Bypass; Humidity; Middle Aged; Pulmonary Circulation; Male; Female
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
giu-1990
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/190070
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 11
social impact