The possibility of reduction of numbers of fresh coumarin and normal plasmas has been studied in a multicentre manual prothrombin (PT) calibration of high international sensitivity index (ISI) rabbit and low ISI human reference thromboplastins at 14 laboratories. The number of calibrant plasmas was reduced progressively by a computer program which generated random numbers to provide 1000 different selections for each reduced sample at each participant laboratory. Results were compared with those of the full set of 20 normal and 60 coumarin plasma calibrations. With the human reagent, 20 coumarins and seven normals still achieved the W.H.O. precision limit (3% CV of the slope), but with the rabbit reagent reduction < 50 coumarins with 17 normal plasmas led to unacceptable CV. Little reduction of numbers from the full set of 80 fresh plasmas appears advisable. For maximum confidence, when calibrating the ISI of a new reagent, it would always seem worthwhile to use the full number of patients' and normal plasmas at each centre for the initial calibration, i.e. 60 fresh coumarin and 20 fresh normal plasmas. Smaller numbers should achieve the required precision with the lower ISI reagent.

The effect of sample size on fresh plasma thromboplastin ISI determination / L. Poller, A.M.H.P. van den Besselaar, J. Jespersen, A. Tripodi, D. Houghton. - In: BRITISH JOURNAL OF HAEMATOLOGY. - ISSN 0007-1048. - 105:3(1999), pp. 655-663.

The effect of sample size on fresh plasma thromboplastin ISI determination

A. Tripodi
Penultimo
;
1999

Abstract

The possibility of reduction of numbers of fresh coumarin and normal plasmas has been studied in a multicentre manual prothrombin (PT) calibration of high international sensitivity index (ISI) rabbit and low ISI human reference thromboplastins at 14 laboratories. The number of calibrant plasmas was reduced progressively by a computer program which generated random numbers to provide 1000 different selections for each reduced sample at each participant laboratory. Results were compared with those of the full set of 20 normal and 60 coumarin plasma calibrations. With the human reagent, 20 coumarins and seven normals still achieved the W.H.O. precision limit (3% CV of the slope), but with the rabbit reagent reduction < 50 coumarins with 17 normal plasmas led to unacceptable CV. Little reduction of numbers from the full set of 80 fresh plasmas appears advisable. For maximum confidence, when calibrating the ISI of a new reagent, it would always seem worthwhile to use the full number of patients' and normal plasmas at each centre for the initial calibration, i.e. 60 fresh coumarin and 20 fresh normal plasmas. Smaller numbers should achieve the required precision with the lower ISI reagent.
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
Settore MED/09 - Medicina Interna
Settore MED/15 - Malattie del Sangue
1999
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/189827
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 14
social impact