Relipidated recombinant tissue factor (r-TF) has been assessed in comparison with conventional rabbit brain thromboplastin (Manchester Reagent) for its suitability for measurement of prothrombin time (PT). The International Sensitivity Index (ISI) of r-TF calibrated against the International Reference Preparation BCT/253 (human plain) was found to be 0.96 and 1.12 with instrumental and manual techniques. Our study of plasmas from patients with congenital deficiencies of clotting factors covering a wide range of severity demonstrates that r-TF is able to detect even minor deficiencies of factors involved in the extrinsic and common coagulation pathways. Patients with liver diseases were correctly diagnosed with a prevalence of abnormal results comparable for both reagents. Between-assay reproducibility expressed as coefficient of variation was 2.3 % and 3.9 % at normal and abnormal PT levels. In conclusion, our evaluation shows that relipidated r-TF possesses the necessary requisites of sensitivity diagnostic accuracy and reproducibility which make it a suitable candidate for PT determination both for monitoring oral anticoagulant therapy and diagnosing congenital and acquired clotting factor deficiencies. Moreover being a highly defined reagent it may constitute a step forward in the standardization of PT testing.

Recombinant tissue factor as substitute for conventional thromboplastin in the prothrombin time test / A. Tripodi, A. Arbini, V. Chantarangkul, P.M. Mannucci. - In: THROMBOSIS AND HAEMOSTASIS. - ISSN 0340-6245. - 67:1(1992), pp. 42-45.

Recombinant tissue factor as substitute for conventional thromboplastin in the prothrombin time test

A. Tripodi
Primo
;
1992

Abstract

Relipidated recombinant tissue factor (r-TF) has been assessed in comparison with conventional rabbit brain thromboplastin (Manchester Reagent) for its suitability for measurement of prothrombin time (PT). The International Sensitivity Index (ISI) of r-TF calibrated against the International Reference Preparation BCT/253 (human plain) was found to be 0.96 and 1.12 with instrumental and manual techniques. Our study of plasmas from patients with congenital deficiencies of clotting factors covering a wide range of severity demonstrates that r-TF is able to detect even minor deficiencies of factors involved in the extrinsic and common coagulation pathways. Patients with liver diseases were correctly diagnosed with a prevalence of abnormal results comparable for both reagents. Between-assay reproducibility expressed as coefficient of variation was 2.3 % and 3.9 % at normal and abnormal PT levels. In conclusion, our evaluation shows that relipidated r-TF possesses the necessary requisites of sensitivity diagnostic accuracy and reproducibility which make it a suitable candidate for PT determination both for monitoring oral anticoagulant therapy and diagnosing congenital and acquired clotting factor deficiencies. Moreover being a highly defined reagent it may constitute a step forward in the standardization of PT testing.
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
Settore MED/09 - Medicina Interna
Settore MED/15 - Malattie del Sangue
1992
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/189434
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 24
  • ???jsp.display-item.citation.isi??? ND
social impact