Model simulation indicates that pressure recorded through a capsule, when lung border is under it, is essentially equal to pressure of pleural liquid (Pliq) surrounding lung border, though only a strip of capsule membrane is exposed to this liquid (the rest is facing diaphragm and lung). At the top of the right 8th or 9th intercostal space of dogs in left lateral posture Pliq recorded through a capsule at transit of lung border during inspiration (bor. I) or expiration (bor. E) was -19.7 +/- 1.1 and -11.2 +/- 0.3 cm H2O, respectively. Pliq recorded simultaneously through a cannula on the flat surface of lung in 5th or 6th intercostal space (corrected for 1 cm lower height) was -18.7 +/- 1.4 and -12.4 +/- 0.8 cm H2O. Similar values of Pliq on lung border and on flat surface of lung, despite different kinds of deformation and different measuring devices, provide further evidence that Pliq is more subatmospheric than pleural surface pressure. Seventy percent of difference in Pliq between bor. I and bor. E was accounted for by: (a) corresponding difference in pleural surface pressure, and (b) greater tidal change of liquid than surface pressure. Possible factors accounting for the remaining 30% are discussed.

Pleural liquid pressure at the caudal border of the lung / E. Agostoni, L. Zocchi, P. G. Agostoni. - In: RESPIRATION PHYSIOLOGY. - ISSN 0034-5687. - 75:1(1989 Jan), pp. 117-28-128. [10.1016/0034-5687(89)90091-1]

Pleural liquid pressure at the caudal border of the lung

E. Agostoni
Primo
;
L. Zocchi
Secondo
;
P.G. Agostoni
Ultimo
1989

Abstract

Model simulation indicates that pressure recorded through a capsule, when lung border is under it, is essentially equal to pressure of pleural liquid (Pliq) surrounding lung border, though only a strip of capsule membrane is exposed to this liquid (the rest is facing diaphragm and lung). At the top of the right 8th or 9th intercostal space of dogs in left lateral posture Pliq recorded through a capsule at transit of lung border during inspiration (bor. I) or expiration (bor. E) was -19.7 +/- 1.1 and -11.2 +/- 0.3 cm H2O, respectively. Pliq recorded simultaneously through a cannula on the flat surface of lung in 5th or 6th intercostal space (corrected for 1 cm lower height) was -18.7 +/- 1.4 and -12.4 +/- 0.8 cm H2O. Similar values of Pliq on lung border and on flat surface of lung, despite different kinds of deformation and different measuring devices, provide further evidence that Pliq is more subatmospheric than pleural surface pressure. Seventy percent of difference in Pliq between bor. I and bor. E was accounted for by: (a) corresponding difference in pleural surface pressure, and (b) greater tidal change of liquid than surface pressure. Possible factors accounting for the remaining 30% are discussed.
Body Fluids; Pleura; Animals; Body Fluid Compartments; Lung; Respiration; Dogs; Pressure; Models, Biological
Settore MED/10 - Malattie dell'Apparato Respiratorio
gen-1989
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/189371
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 11
social impact