Charged particle (π/K) separation in the momentum range 0.5-0.7 GeV/c using a new method of shape analysis of the signal from a liquid krypton ionization chamber has been studied experimentally. The detector has been exposed to pions and protons at the T11 test beam at CERN PS. The shape of preamplifier output signal has been recorded by a waveform digitizer and differentiated to obtain multiple measurements of induced current inside a 2 cm gap. Results on particle separation are presented and compared with a Monte Carlo simulation.

Particle identification in a LKr ionization chamber by multiple induced current measurements using the shape analysis of the signal / R. Diaferia, F. Lanni, B. Maggi, F. Palombo, A. Sala, P. Cantoni, P. Frabetti, L. Stagni. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 368:2(1996), pp. 339-344.

Particle identification in a LKr ionization chamber by multiple induced current measurements using the shape analysis of the signal

F. Palombo;
1996

Abstract

Charged particle (π/K) separation in the momentum range 0.5-0.7 GeV/c using a new method of shape analysis of the signal from a liquid krypton ionization chamber has been studied experimentally. The detector has been exposed to pions and protons at the T11 test beam at CERN PS. The shape of preamplifier output signal has been recorded by a waveform digitizer and differentiated to obtain multiple measurements of induced current inside a 2 cm gap. Results on particle separation are presented and compared with a Monte Carlo simulation.
English
Settore FIS/04 - Fisica Nucleare e Subnucleare
Articolo
Sì, ma tipo non specificato
1996
368
2
339
344
Pubblicato
Periodico con rilevanza internazionale
CrossRef
info:eu-repo/semantics/article
Particle identification in a LKr ionization chamber by multiple induced current measurements using the shape analysis of the signal / R. Diaferia, F. Lanni, B. Maggi, F. Palombo, A. Sala, P. Cantoni, P. Frabetti, L. Stagni. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 368:2(1996), pp. 339-344.
none
Prodotti della ricerca::01 - Articolo su periodico
8
262
Article (author)
no
R. Diaferia, F. Lanni, B. Maggi, F. Palombo, A. Sala, P. Cantoni, P. Frabetti, L. Stagni
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/184360
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
  • OpenAlex ND
social impact