We investigated the effects of body mass index (BMI) on functional residual capacity (FRC), respiratory mechanics (compliance and resistance), gas exchange, and the inspiratory mechanical work done per liter of ventilation during general anesthesia. We used the esophageal balloon technique, together with rapid airway occlusion during constant inspiratory flow, to partition the mechanics of the respiratory system into its pulmonary and chest wall components. FRC was measured by using the helium dilution technique. We studied 24 consecutive and unselected patients during general anesthesia, before surgical intervention, in the supine position (8 normal subjects with a BMI < or = 25 kg/m2, 8 moderately obese patients with a BMI >25 kg/m2 and <40 kg/m2, and 8 morbidly obese patients with a BMI > or = 40 kg/m2). We found that, with increasing BMI: 1. FRC decreased exponentially (r = 0.86; P < 0.01) 2. the compliance of the total respiratory system and of the lung decreased exponentially (r = 0.86; P < 0.01 and r = 0.81; P < 0.01, respectively), whereas the compliance of the chest wall was only minimally affected (r = 0.45; P < 0.05) 3. the resistance of the total respiratory system and of the lung increased (r = 0.81; P < 0.01 and r = 0.84; P < 0.01, respectively), whereas the chest wall resistance was unaffected (r = 0.06; P = not significant) 4. the oxygenation index (PaO2/PAO2) decreased exponentially (r = 0.81; P < 0.01) and was correlated with FRC (r = 0.62; P < 0.01), whereas PaCO2 was unaffected (r = 0.06; P = not significant) 5. the work of breathing of the total respiratory system increased, mainly due to the lung component (r = 0.88; P < 0.01 and r = 0.81; P < 0.01, respectively). In conclusion, BMI is an important determinant of lung volumes, respiratory mechanics, and oxygenation during general anesthesia with patients in the supine position. IMPLICATIONS: The aim of this study was to investigate the influence of body mass on lung volumes, respiratory mechanics, and gas exchange during general anesthesia.

The effects of body mass on lung volumes, respiratory mechanics, and gas exchange during general anesthesia / P. Pelosi, M. Croci, I. Ravagnan, S. Tredici, A. Pedoto, A. Lissoni, L. Gattinoni. - In: ANESTHESIA AND ANALGESIA. - ISSN 0003-2999. - 87:3(1998 Sep), pp. 654-60-660. [10.1213/00000539-199809000-00031]

The effects of body mass on lung volumes, respiratory mechanics, and gas exchange during general anesthesia

L. Gattinoni
Ultimo
1998

Abstract

We investigated the effects of body mass index (BMI) on functional residual capacity (FRC), respiratory mechanics (compliance and resistance), gas exchange, and the inspiratory mechanical work done per liter of ventilation during general anesthesia. We used the esophageal balloon technique, together with rapid airway occlusion during constant inspiratory flow, to partition the mechanics of the respiratory system into its pulmonary and chest wall components. FRC was measured by using the helium dilution technique. We studied 24 consecutive and unselected patients during general anesthesia, before surgical intervention, in the supine position (8 normal subjects with a BMI < or = 25 kg/m2, 8 moderately obese patients with a BMI >25 kg/m2 and <40 kg/m2, and 8 morbidly obese patients with a BMI > or = 40 kg/m2). We found that, with increasing BMI: 1. FRC decreased exponentially (r = 0.86; P < 0.01) 2. the compliance of the total respiratory system and of the lung decreased exponentially (r = 0.86; P < 0.01 and r = 0.81; P < 0.01, respectively), whereas the compliance of the chest wall was only minimally affected (r = 0.45; P < 0.05) 3. the resistance of the total respiratory system and of the lung increased (r = 0.81; P < 0.01 and r = 0.84; P < 0.01, respectively), whereas the chest wall resistance was unaffected (r = 0.06; P = not significant) 4. the oxygenation index (PaO2/PAO2) decreased exponentially (r = 0.81; P < 0.01) and was correlated with FRC (r = 0.62; P < 0.01), whereas PaCO2 was unaffected (r = 0.06; P = not significant) 5. the work of breathing of the total respiratory system increased, mainly due to the lung component (r = 0.88; P < 0.01 and r = 0.81; P < 0.01, respectively). In conclusion, BMI is an important determinant of lung volumes, respiratory mechanics, and oxygenation during general anesthesia with patients in the supine position. IMPLICATIONS: The aim of this study was to investigate the influence of body mass on lung volumes, respiratory mechanics, and gas exchange during general anesthesia.
Airway Resistance; Functional Residual Capacity; Humans; Anesthesia, General; Aged; Obesity, Morbid; Body Mass Index; Tidal Volume; Pulmonary Gas Exchange; Oxygen; Work of Breathing; Respiratory Mechanics; Adult; Middle Aged; Lung Volume Measurements; Female; Male
Settore MED/41 - Anestesiologia
set-1998
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/184189
Citazioni
  • ???jsp.display-item.citation.pmc??? 117
  • Scopus 494
  • ???jsp.display-item.citation.isi??? ND
social impact