Atrial fibrillation (AF) is characterized by desynchronization of atrial electrical activity causing a consequent irregular ventricular response. In AF, the beat-to-beat variation of blood pressure is increased because of variations in filling time and contractility. However, only a few studies have analyzed short-term blood pressure variations in AF, and we have recently observed a harmonic low-frequency (LF) component in systolic arterial pressure (SAP) during AF. Aim of the present study is to propose a method to verify the reliability of the spectral component found in SAP series, based on the position of the poles of the autoregressive spectral decomposition in the z-plane. In particular, 1,000 random permutations of the series allowed the definition of an area in the z-plane where poles from random process are likely to occur. Poles lying outside this area are considered as reliable oscillations. We tested the method on 53 recordings obtained at rest from patients with persistent AF. LF component was found in, respectively, 51 and 43 recordings in SAP and RR series. High-frequency (HF) component was found in all the recordings for both SAP and RR series. Using the proposed test, the percentage of reliable components in LF and HF bands was 80 and 38 in SAP series, and 20 and 18 in RR series. We concluded that, at variance with RR ones, SAP LF components are likely to represent true physiological oscillations

On the reliability of frequency components in systolic arterial pressare in patients with atrial fibrillation / V.D.A. Corino, F. Lombardi, L. Mainardi. - In: MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING. - ISSN 0140-0118. - 48:4(2010), pp. 381-387. [10.1007/s11517-010-0588-z]

On the reliability of frequency components in systolic arterial pressare in patients with atrial fibrillation

F. Lombardi
Secondo
;
2010

Abstract

Atrial fibrillation (AF) is characterized by desynchronization of atrial electrical activity causing a consequent irregular ventricular response. In AF, the beat-to-beat variation of blood pressure is increased because of variations in filling time and contractility. However, only a few studies have analyzed short-term blood pressure variations in AF, and we have recently observed a harmonic low-frequency (LF) component in systolic arterial pressure (SAP) during AF. Aim of the present study is to propose a method to verify the reliability of the spectral component found in SAP series, based on the position of the poles of the autoregressive spectral decomposition in the z-plane. In particular, 1,000 random permutations of the series allowed the definition of an area in the z-plane where poles from random process are likely to occur. Poles lying outside this area are considered as reliable oscillations. We tested the method on 53 recordings obtained at rest from patients with persistent AF. LF component was found in, respectively, 51 and 43 recordings in SAP and RR series. High-frequency (HF) component was found in all the recordings for both SAP and RR series. Using the proposed test, the percentage of reliable components in LF and HF bands was 80 and 38 in SAP series, and 20 and 18 in RR series. We concluded that, at variance with RR ones, SAP LF components are likely to represent true physiological oscillations
Arterial pressure variability; Autoregressive spectral analysis; Baroreflex mechanisms; Rhythmical oscillations
Settore MED/11 - Malattie dell'Apparato Cardiovascolare
2010
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/180032
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
  • OpenAlex ND
social impact