A prototype liquid argon preshower detector with a strip granularity of 2.5 mm has been tested at the CERN SPS in front of a liquid argon Accordion calorimeter. For charged tracks a signal-to-noise ratio of 9.4 and a space resolution of 340 mum were measured; the rejection power against overlapping photons produced in the decay of 50 GeV pi0's is larger than 3; the precision on the electromagnetic shower direction, determined together with the calorimeter, is better than 7 mrad above 40 GeV; the calorimeter performance behind the preshower (approximately 4X0) is fully preserved. These results make such a detector attractive for future operation at the CERN Large Hadron Collider.

PERFORMANCE OF A LIQUID ARGON PRESHOWER DETECTOR INTEGRATED WITH AN ACCORDION CALORIMETER / B. AUBERT, A. BAZAN, B. BEAUGIRAUD, J. COLAS, T. LEFLOUR, M. MAIRE, J. VIALLE, I. WINGERTERSEEZ, Y. ZOLNIEROWSKI, H. GORDON, V. RADEKA, D. RAHM, D. STEPHANI, N. BULGAKOV, J. CHEVALLEY, C. FABJAN, D. FOURNIER, O. GILDEMEISTER, P. JENNI, M. NESSI, F. NESSITEDALDI, M. PEPE, W. RICHTER, J. SODERQVIST, V. VUILLEMIN, J. BAZE, L. GOSSET, P. LAVOCAT, J. LOTTIN, B. MANSOULIE, J. MEYER, J. RENARDY, J. TEIGER, H. ZACCONE, G. BATTISTONI, D. CAMIN, D. CAVALLI, G. COSTA, A. CRAVERO, A. FERRARI, F. GIANOTTI, L. MANDELLI, M. MAZZANTI, L. PERINI, G. PESSINA, M. SCIAMANNA, E. AUGE, R. CHASE, J. CHOLLET, C. DELATAILLE, L. FAYARD, A. HRISOHO, P. JEAN, G. LEMEUR, B. MERKEL, J. NOPPE, G. PARROUR, P. PETROFF, J. REPELLIN, A. SCHAFFER, N. SEGUIN, G. UNAL, C. FUGLESANG, M. LEFEBVRE. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 330:3(1993), pp. 405-415. [10.1016/0168-9002(93)90569-4]

PERFORMANCE OF A LIQUID ARGON PRESHOWER DETECTOR INTEGRATED WITH AN ACCORDION CALORIMETER

L. Perini;
1993

Abstract

A prototype liquid argon preshower detector with a strip granularity of 2.5 mm has been tested at the CERN SPS in front of a liquid argon Accordion calorimeter. For charged tracks a signal-to-noise ratio of 9.4 and a space resolution of 340 mum were measured; the rejection power against overlapping photons produced in the decay of 50 GeV pi0's is larger than 3; the precision on the electromagnetic shower direction, determined together with the calorimeter, is better than 7 mrad above 40 GeV; the calorimeter performance behind the preshower (approximately 4X0) is fully preserved. These results make such a detector attractive for future operation at the CERN Large Hadron Collider.
English
Settore FIS/04 - Fisica Nucleare e Subnucleare
Articolo
Esperti anonimi
1993
330
3
405
415
Pubblicato
Periodico con rilevanza internazionale
info:eu-repo/semantics/article
PERFORMANCE OF A LIQUID ARGON PRESHOWER DETECTOR INTEGRATED WITH AN ACCORDION CALORIMETER / B. AUBERT, A. BAZAN, B. BEAUGIRAUD, J. COLAS, T. LEFLOUR, M. MAIRE, J. VIALLE, I. WINGERTERSEEZ, Y. ZOLNIEROWSKI, H. GORDON, V. RADEKA, D. RAHM, D. STEPHANI, N. BULGAKOV, J. CHEVALLEY, C. FABJAN, D. FOURNIER, O. GILDEMEISTER, P. JENNI, M. NESSI, F. NESSITEDALDI, M. PEPE, W. RICHTER, J. SODERQVIST, V. VUILLEMIN, J. BAZE, L. GOSSET, P. LAVOCAT, J. LOTTIN, B. MANSOULIE, J. MEYER, J. RENARDY, J. TEIGER, H. ZACCONE, G. BATTISTONI, D. CAMIN, D. CAVALLI, G. COSTA, A. CRAVERO, A. FERRARI, F. GIANOTTI, L. MANDELLI, M. MAZZANTI, L. PERINI, G. PESSINA, M. SCIAMANNA, E. AUGE, R. CHASE, J. CHOLLET, C. DELATAILLE, L. FAYARD, A. HRISOHO, P. JEAN, G. LEMEUR, B. MERKEL, J. NOPPE, G. PARROUR, P. PETROFF, J. REPELLIN, A. SCHAFFER, N. SEGUIN, G. UNAL, C. FUGLESANG, M. LEFEBVRE. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 330:3(1993), pp. 405-415. [10.1016/0168-9002(93)90569-4]
none
Prodotti della ricerca::01 - Articolo su periodico
64
262
Article (author)
no
B. Aubert, A. Bazan, B. Beaugiraud, J. Colas, T. Leflour, M. Maire, J. Vialle, I. Wingerterseez, Y. Zolnierowski, H. Gordon, V. Radeka, D. Rahm, D. St...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/179987
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 12
  • OpenAlex ND
social impact