A prototype lead-liquid-argon electromagnetic calorimeter with parallel plates and Accordion geometry has been equipped with high speed readout electronics and tested with electron and muon beams at the CERN SPS. For a response peaking time of about 35 ns, fast enough for operation at the future hadron colliders, the energy resolution for electrons is 9.6%/ square-root E[GeV] with a local constant term of 0.3% and a noise contribution of 0.33/E[GeV]. The spatial accuracy achieved with a detector granularity of 2.7 cm is 3.7 mm/ square-root E[GeV] and the angular resolution 12 mrad at 60 GeV.
PERFORMANCE OF A LIQUID ARGON ACCORDION CALORIMETER WITH FAST READOUT / B. AUBERT, A. BAZAN, B. BEAUGIRAUD, J. COLAS, T. LEFLOUR, M. MAIRE, J. VIALLE, I. WINGERTERSEEZ, Y. ZOLNIEROWSKI, H. GORDON, V. RADEKA, D. RAHM, D. STEPHANI, J. CHEVALLEY, C. FABJAN, D. FOURNIER, A. FRANZ, O. GILDEMEISTER, P. JENNI, M. NESSI, F. NESSITEDALDI, M. PEPE, W. RICHTER, J. SODERQVIST, J. BAZE, L. GOSSET, P. LAVOCAT, J. LOTTIN, B. MANSOULIE, J. MEYER, J. RENARDY, J. TEIGER, H. ZACCONE, G. BATTISTONI, D. CAMIN, D. CAVALLI, G. COSTA, A. CRAVERO, A. FERRARI, F. GIANOTTI, L. MANDELLI, M. MAZZANTI, L. PERINI, G. PESSINA, P. SALA, M. SCIAMANNA, E. AUGE, R. CHASE, J. CHOLLET, C. DELATAILLE, L. FAYARD, P. JEAN, L. ICONOMIDOUFAYARD, B. MERKEL, J. NOPPE, G. PARROUR, P. PETROFF, J. REPELLIN, A. SCHAFFER, N. SEGUIN, G. UNAL, C. FUGLESANG, M. LEFEBVRE, S. TOWERS. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 321:3(1992), pp. 467-478. [10.1016/0168-9002(92)90056-A]
PERFORMANCE OF A LIQUID ARGON ACCORDION CALORIMETER WITH FAST READOUT
A prototype lead-liquid-argon electromagnetic calorimeter with parallel plates and Accordion geometry has been equipped with high speed readout electronics and tested with electron and muon beams at the CERN SPS. For a response peaking time of about 35 ns, fast enough for operation at the future hadron colliders, the energy resolution for electrons is 9.6%/ square-root E[GeV] with a local constant term of 0.3% and a noise contribution of 0.33/E[GeV]. The spatial accuracy achieved with a detector granularity of 2.7 cm is 3.7 mm/ square-root E[GeV] and the angular resolution 12 mrad at 60 GeV.
PERFORMANCE OF A LIQUID ARGON ACCORDION CALORIMETER WITH FAST READOUT / B. AUBERT, A. BAZAN, B. BEAUGIRAUD, J. COLAS, T. LEFLOUR, M. MAIRE, J. VIALLE, I. WINGERTERSEEZ, Y. ZOLNIEROWSKI, H. GORDON, V. RADEKA, D. RAHM, D. STEPHANI, J. CHEVALLEY, C. FABJAN, D. FOURNIER, A. FRANZ, O. GILDEMEISTER, P. JENNI, M. NESSI, F. NESSITEDALDI, M. PEPE, W. RICHTER, J. SODERQVIST, J. BAZE, L. GOSSET, P. LAVOCAT, J. LOTTIN, B. MANSOULIE, J. MEYER, J. RENARDY, J. TEIGER, H. ZACCONE, G. BATTISTONI, D. CAMIN, D. CAVALLI, G. COSTA, A. CRAVERO, A. FERRARI, F. GIANOTTI, L. MANDELLI, M. MAZZANTI, L. PERINI, G. PESSINA, P. SALA, M. SCIAMANNA, E. AUGE, R. CHASE, J. CHOLLET, C. DELATAILLE, L. FAYARD, P. JEAN, L. ICONOMIDOUFAYARD, B. MERKEL, J. NOPPE, G. PARROUR, P. PETROFF, J. REPELLIN, A. SCHAFFER, N. SEGUIN, G. UNAL, C. FUGLESANG, M. LEFEBVRE, S. TOWERS. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 321:3(1992), pp. 467-478. [10.1016/0168-9002(92)90056-A]
none
Prodotti della ricerca::01 - Articolo su periodico
64
262
Article (author)
Periodico senza Impact Factor
B. Aubert, A. Bazan, B. Beaugiraud, J. Colas, T. Leflour, M. Maire, J. Vialle, I. Wingerterseez, Y. Zolnierowski, H. Gordon, V. Radeka, D. Rahm, D. St...espandi
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/179983
Citazioni
ND
30
28
ND
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.