Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
IRIS Institutional Research Information System - AIR Archivio Istituzionale della Ricerca
A trigger system has been designed and built to select events containing high pT electromagnetic showers detected in a large calorimeter with orthogonal readout. The electronics include analog adders with up to 123 inputs, pulse shapers with 20 ns integration time, 100 MHz flash ADCs and ECL loop-up tables. The total number of input channels is 3072 and the trigger decision is made in about 120 ns.
HIGH PT TRIGGER ELECTRONICS FOR A LARGE ORTHOGONAL READOUT ELECTROMAGNETIC CALORIMETER / P. BENE, M. BONESINI, E. BONVIN, J. BOVIER, L. CARROLL, A. CASS, D. CAVALLI, G. CECCHET, G. COSTA, M. DONNAT, P. DORSAZ, J. FISCHER, L. FLURI, D. FRAME, F. GIANOTTI, S. JACK, J. JACKSON, M. KELLY, M. KIENZLEFOCACCI, R. LUCOCK, J. LYNCH, L. MANDELLI, M. MARTIN, L. MATHYS, A. MAXWELL, M. MAZZANTI, J. MYERSCOUGH, P. NEGUS, S. PENSOTTIRANCOITA, L. PERINI, D. PERRIN, W. RANGE, J. RICHEUX, L. ROSSELET, A. RUCKSTUHL, J. RUTSCHMANN, S. SNOW, A. THOMPSON, R. TURNBULL, J. WELLS, M. WERLEN. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 270:1(1988), pp. 21-31.
HIGH PT TRIGGER ELECTRONICS FOR A LARGE ORTHOGONAL READOUT ELECTROMAGNETIC CALORIMETER
A trigger system has been designed and built to select events containing high pT electromagnetic showers detected in a large calorimeter with orthogonal readout. The electronics include analog adders with up to 123 inputs, pulse shapers with 20 ns integration time, 100 MHz flash ADCs and ECL loop-up tables. The total number of input channels is 3072 and the trigger decision is made in about 120 ns.
HIGH PT TRIGGER ELECTRONICS FOR A LARGE ORTHOGONAL READOUT ELECTROMAGNETIC CALORIMETER / P. BENE, M. BONESINI, E. BONVIN, J. BOVIER, L. CARROLL, A. CASS, D. CAVALLI, G. CECCHET, G. COSTA, M. DONNAT, P. DORSAZ, J. FISCHER, L. FLURI, D. FRAME, F. GIANOTTI, S. JACK, J. JACKSON, M. KELLY, M. KIENZLEFOCACCI, R. LUCOCK, J. LYNCH, L. MANDELLI, M. MARTIN, L. MATHYS, A. MAXWELL, M. MAZZANTI, J. MYERSCOUGH, P. NEGUS, S. PENSOTTIRANCOITA, L. PERINI, D. PERRIN, W. RANGE, J. RICHEUX, L. ROSSELET, A. RUCKSTUHL, J. RUTSCHMANN, S. SNOW, A. THOMPSON, R. TURNBULL, J. WELLS, M. WERLEN. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 270:1(1988), pp. 21-31.
none
Prodotti della ricerca::01 - Articolo su periodico
41
262
Article (author)
no
P. BENE, M. BONESINI, E. BONVIN, J. BOVIER, L. CARROLL, A. CASS, D. CAVALLI, G. CECCHET, G. COSTA, M. DONNAT, P. DORSAZ, J. FISCHER, L. FLURI, D. FRAM...espandi
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/179968
Citazioni
ND
4
4
ND
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.