A 1152 channel timing system used with a large electromagnetic calorimeter is described. Analysis of the timing information from the vertical and horizontal elements of the calorimeter yielded values for the position coordinates of the showers. This information was used to resolve ambiguities in the pattern recognition arising from multiple showers. A resolution of better than 0.25 ns for all channels was achieved. The calibration methods employed to maintain this resolution over several years are discussed.

A 1152 CHANNEL TIMING SYSTEM FOR AN ELECTROMAGNETIC CALORIMETER READOUT / M. BONESINI, E. BONVIN, P. BOOTH, L. CARROLL, A. CASS, D. CAVALLI, G. CECCHET, G. COSTA, M. DONNAT, P. DORSAZ, D. EDWARDS, J. FISCHER, L. FLURI, D. FRAME, F. GIANOTTI, S. JACK, J. JACKSON, M. KELLY, M. KIENZLEFOCACCI, R. LUCOCK, J. LYNCH, L. MANDELLI, M. MARTIN, L. MATHYS, A. MAXWELL, M. MAZZANTI, J. MYERSCOUGH, P. NEGUS, S. PENSOTTIRANCOITA, L. PERINI, D. PERRIN, W. RANGE, L. ROSSELET, J. RUTSCHMANN, S. SNOW, M. TAMBORINI, A. THOMPSON, R. TURNBULL, J. WELLS, M. WERLEN. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 263:2-3(1988), pp. 325-332. [10.1016/0168-9002(88)90967-9]

A 1152 CHANNEL TIMING SYSTEM FOR AN ELECTROMAGNETIC CALORIMETER READOUT

L. Perini;
1988

Abstract

A 1152 channel timing system used with a large electromagnetic calorimeter is described. Analysis of the timing information from the vertical and horizontal elements of the calorimeter yielded values for the position coordinates of the showers. This information was used to resolve ambiguities in the pattern recognition arising from multiple showers. A resolution of better than 0.25 ns for all channels was achieved. The calibration methods employed to maintain this resolution over several years are discussed.
English
Settore FIS/04 - Fisica Nucleare e Subnucleare
Articolo
Esperti anonimi
1988
263
2-3
325
332
Pubblicato
Periodico con rilevanza internazionale
info:eu-repo/semantics/article
A 1152 CHANNEL TIMING SYSTEM FOR AN ELECTROMAGNETIC CALORIMETER READOUT / M. BONESINI, E. BONVIN, P. BOOTH, L. CARROLL, A. CASS, D. CAVALLI, G. CECCHET, G. COSTA, M. DONNAT, P. DORSAZ, D. EDWARDS, J. FISCHER, L. FLURI, D. FRAME, F. GIANOTTI, S. JACK, J. JACKSON, M. KELLY, M. KIENZLEFOCACCI, R. LUCOCK, J. LYNCH, L. MANDELLI, M. MARTIN, L. MATHYS, A. MAXWELL, M. MAZZANTI, J. MYERSCOUGH, P. NEGUS, S. PENSOTTIRANCOITA, L. PERINI, D. PERRIN, W. RANGE, L. ROSSELET, J. RUTSCHMANN, S. SNOW, M. TAMBORINI, A. THOMPSON, R. TURNBULL, J. WELLS, M. WERLEN. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 263:2-3(1988), pp. 325-332. [10.1016/0168-9002(88)90967-9]
none
Prodotti della ricerca::01 - Articolo su periodico
40
262
Article (author)
Periodico senza Impact Factor
M. Bonesini, E. Bonvin, P. Booth, L. Carroll, A. Cass, D. Cavalli, G. Cecchet, G. Costa, M. Donnat, P. Dorsaz, D. Edwards, J. Fischer, L. Fluri, D. Fr...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/179966
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 4
  • OpenAlex ND
social impact