A 1152 channel timing system used with a large electromagnetic calorimeter is described. Analysis of the timing information from the vertical and horizontal elements of the calorimeter yielded values for the position coordinates of the showers. This information was used to resolve ambiguities in the pattern recognition arising from multiple showers. A resolution of better than 0.25 ns for all channels was achieved. The calibration methods employed to maintain this resolution over several years are discussed.
A 1152 CHANNEL TIMING SYSTEM FOR AN ELECTROMAGNETIC CALORIMETER READOUT / M. BONESINI, E. BONVIN, P. BOOTH, L. CARROLL, A. CASS, D. CAVALLI, G. CECCHET, G. COSTA, M. DONNAT, P. DORSAZ, D. EDWARDS, J. FISCHER, L. FLURI, D. FRAME, F. GIANOTTI, S. JACK, J. JACKSON, M. KELLY, M. KIENZLEFOCACCI, R. LUCOCK, J. LYNCH, L. MANDELLI, M. MARTIN, L. MATHYS, A. MAXWELL, M. MAZZANTI, J. MYERSCOUGH, P. NEGUS, S. PENSOTTIRANCOITA, L. PERINI, D. PERRIN, W. RANGE, L. ROSSELET, J. RUTSCHMANN, S. SNOW, M. TAMBORINI, A. THOMPSON, R. TURNBULL, J. WELLS, M. WERLEN. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 263:2-3(1988), pp. 325-332. [10.1016/0168-9002(88)90967-9]
A 1152 CHANNEL TIMING SYSTEM FOR AN ELECTROMAGNETIC CALORIMETER READOUT
A 1152 channel timing system used with a large electromagnetic calorimeter is described. Analysis of the timing information from the vertical and horizontal elements of the calorimeter yielded values for the position coordinates of the showers. This information was used to resolve ambiguities in the pattern recognition arising from multiple showers. A resolution of better than 0.25 ns for all channels was achieved. The calibration methods employed to maintain this resolution over several years are discussed.
A 1152 CHANNEL TIMING SYSTEM FOR AN ELECTROMAGNETIC CALORIMETER READOUT / M. BONESINI, E. BONVIN, P. BOOTH, L. CARROLL, A. CASS, D. CAVALLI, G. CECCHET, G. COSTA, M. DONNAT, P. DORSAZ, D. EDWARDS, J. FISCHER, L. FLURI, D. FRAME, F. GIANOTTI, S. JACK, J. JACKSON, M. KELLY, M. KIENZLEFOCACCI, R. LUCOCK, J. LYNCH, L. MANDELLI, M. MARTIN, L. MATHYS, A. MAXWELL, M. MAZZANTI, J. MYERSCOUGH, P. NEGUS, S. PENSOTTIRANCOITA, L. PERINI, D. PERRIN, W. RANGE, L. ROSSELET, J. RUTSCHMANN, S. SNOW, M. TAMBORINI, A. THOMPSON, R. TURNBULL, J. WELLS, M. WERLEN. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 263:2-3(1988), pp. 325-332. [10.1016/0168-9002(88)90967-9]
none
Prodotti della ricerca::01 - Articolo su periodico
40
262
Article (author)
Periodico senza Impact Factor
M. Bonesini, E. Bonvin, P. Booth, L. Carroll, A. Cass, D. Cavalli, G. Cecchet, G. Costa, M. Donnat, P. Dorsaz, D. Edwards, J. Fischer, L. Fluri, D. Fr...espandi
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/179966
Citazioni
ND
3
4
ND
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.