Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
IRIS Institutional Research Information System - AIR Archivio Istituzionale della Ricerca
A test model has been built to study the performance of prototypes for the ALEPH Time Projection Chamber. The device consists of a solenoid magnet providing a magnetic field up to 1.2 T inside a cylindric field cage of 75 cm diameter and 1.3 m length. It has been used to test two chambers of different design. We describe the setup and present results from measurements with these prototype chambers using laser beams and cosmic ray particles.
TPC90, a test model for the ALEPH time projection chamber / S.R. Amendolia, R. Benetta, M. Binder, W. Blum, A. Caldwell, M. Cherney, D.F. Cowen, D. Demille, A. Farilla, F. Fidecaro, Y.N. Guo, J.M. Izen, R.C. Jared, W. Kilgore, K. Kleinknecht, I. Lehraus, F. Liello, J.J. Love, A. Lusiani, P. Maas, P.S. Marrocchesi, R. Matthewson, J. May, M. Mermikides, E. Milotti, A. Minten, E. Monnier, D. Muller, A. Peisert, M. Price, F. Ragusa, C. Raine, J. Richstein, R. Richter, L. Rolandi, G. Sanguinetti, W. Schlatter, J. Sedgebeer, R. Settles, G. Sinnis, K. Smith, G. Stefanini, U. Stierlin, M. Takashima, W. Tejessy, J. Thomas, A. Vayaki, J. Wells, E. Wicklund, W. Witzeling, S. Wu, W. Wu. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 252:2/3(1986), pp. 392-398.
TPC90, a test model for the ALEPH time projection chamber
S. R. Amendolia;R. Benetta;M. Binder;W. Blum;A. Caldwell;M. Cherney;D. F. Cowen;D. Demille;A. Farilla;F. Fidecaro;Y. N. Guo;J. M. Izen;R. C. Jared;W. Kilgore;K. Kleinknecht;I. Lehraus;F. Liello;J. J. Love;A. Lusiani;P. Maas;P. S. Marrocchesi;R. Matthewson;J. May;M. Mermikides;E. Milotti;A. Minten;E. Monnier;D. Muller;A. Peisert;M. Price;F. Ragusa;C. Raine;J. Richstein;R. Richter;L. Rolandi;G. Sanguinetti;W. Schlatter;J. Sedgebeer;R. Settles;G. Sinnis;K. Smith;G. Stefanini;U. Stierlin;M. Takashima;W. Tejessy;J. Thomas;A. Vayaki;J. Wells;E. Wicklund;W. Witzeling;S. Wu;W. Wu
1986
Abstract
A test model has been built to study the performance of prototypes for the ALEPH Time Projection Chamber. The device consists of a solenoid magnet providing a magnetic field up to 1.2 T inside a cylindric field cage of 75 cm diameter and 1.3 m length. It has been used to test two chambers of different design. We describe the setup and present results from measurements with these prototype chambers using laser beams and cosmic ray particles.
TPC90, a test model for the ALEPH time projection chamber / S.R. Amendolia, R. Benetta, M. Binder, W. Blum, A. Caldwell, M. Cherney, D.F. Cowen, D. Demille, A. Farilla, F. Fidecaro, Y.N. Guo, J.M. Izen, R.C. Jared, W. Kilgore, K. Kleinknecht, I. Lehraus, F. Liello, J.J. Love, A. Lusiani, P. Maas, P.S. Marrocchesi, R. Matthewson, J. May, M. Mermikides, E. Milotti, A. Minten, E. Monnier, D. Muller, A. Peisert, M. Price, F. Ragusa, C. Raine, J. Richstein, R. Richter, L. Rolandi, G. Sanguinetti, W. Schlatter, J. Sedgebeer, R. Settles, G. Sinnis, K. Smith, G. Stefanini, U. Stierlin, M. Takashima, W. Tejessy, J. Thomas, A. Vayaki, J. Wells, E. Wicklund, W. Witzeling, S. Wu, W. Wu. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 252:2/3(1986), pp. 392-398.
none
Prodotti della ricerca::01 - Articolo su periodico
52
262
Article (author)
no
S.R. Amendolia, R. Benetta, M. Binder, W. Blum, A. Caldwell, M. Cherney, D.F. Cowen, D. Demille, A. Farilla, F. Fidecaro, Y.N. Guo, J.M. Izen, R.C. Ja...espandi
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/175276
Citazioni
ND
8
7
ND
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.