Objective: To compare intra-partum performance of trans-abdominal electrocardiogram with Doppler telemetry. Methods: In this prospective longitudinal study, simultaneous monitoring with trans-abdominal ECG and Doppler telemetry was performed in 41 uncomplicated term singleton pregnancies during labour. Results: The overall success rate for FHR monitoring was similar between trans-abdominal ECG and Doppler telemetry (88.5 ± 16.7% vs 89.4 ± 7.6%), except for the second stage of labour. A significantly higher rate of confusion (p < 0.001) between fetal and maternal heart was found for Doppler telemetry (4.5 ± 4.5%) compared with trans-abdominal ECG (1.3 ± 1.9%), especially in the second stage and during maternal movements. Conclusions: Trans-abdominal ECG monitoring is feasible, with comparable success rate to traditional Doppler telemetry, without interfering with maternal mobility or requiring midwife intervention. The reduction in maternal\fetal heart rate confusion from trans-abdominal ECG could reduce incorrect obstetric interpretation.

Fetal and maternal heart rate confusion during intra-partum monitoring : comparison of trans-abdominal fetal electrocardiogram and Doppler telemetry / T. Stampalija, M. Signaroldi, C. Mastroianni, E. Rosti, V. Signorelli, D. Casati, E.M. Ferrazzi. - In: THE JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE. - ISSN 1476-7058. - 25:8(2012 Aug), pp. 1517-1520.

Fetal and maternal heart rate confusion during intra-partum monitoring : comparison of trans-abdominal fetal electrocardiogram and Doppler telemetry

T. Stampalija;E.M. Ferrazzi
2012

Abstract

Objective: To compare intra-partum performance of trans-abdominal electrocardiogram with Doppler telemetry. Methods: In this prospective longitudinal study, simultaneous monitoring with trans-abdominal ECG and Doppler telemetry was performed in 41 uncomplicated term singleton pregnancies during labour. Results: The overall success rate for FHR monitoring was similar between trans-abdominal ECG and Doppler telemetry (88.5 ± 16.7% vs 89.4 ± 7.6%), except for the second stage of labour. A significantly higher rate of confusion (p < 0.001) between fetal and maternal heart was found for Doppler telemetry (4.5 ± 4.5%) compared with trans-abdominal ECG (1.3 ± 1.9%), especially in the second stage and during maternal movements. Conclusions: Trans-abdominal ECG monitoring is feasible, with comparable success rate to traditional Doppler telemetry, without interfering with maternal mobility or requiring midwife intervention. The reduction in maternal\fetal heart rate confusion from trans-abdominal ECG could reduce incorrect obstetric interpretation.
Doppler telemetry; intra-partum fetal monitoring; labour; trans-abdominal fetal ECG
Settore MED/40 - Ginecologia e Ostetricia
ago-2012
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/172199
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 27
  • ???jsp.display-item.citation.isi??? 25
social impact