Since its introduction in 1996, the Genesis II Total Knee System has produced good clinical results in patients undergoing primary total knee replacement. A systematic review of the literature–the first of its kind for this device–was undertaken to collect data on the Genesis II in order to provide a better understanding of its medium- to long-term performance. Of 124 Genesis II-related studies published in the literature, 11 met the eligibility criteria and were included in the final analysis. The included studies had a mean follow-up length of 38.1 months. Data from 1201 knees were available for review. Patients were an average of 70.5 years of age and predominantly female (63%). Findings indicated that the revision rate with this implant is low with up to 11.9 years of follow-up, with 14 revisions in total. The survival rate ranged from 100% at 1 and 2 years to 96.0% at 11.9 years. The mean Knee Society knee score improved 51.0 points from preoperative to postoperative evaluation. In conclusion, the Genesis II exhibited good clinical performance with up to 11 years follow-up, with an encouraging rate of survival and improvement in function. Additional studies with larger sample sizes and longer follow-up periods are needed to better understand the long-term performance of this implant.

The Genesis II in primary total knee replacement : A systematic literature review of clinical outcomes / M. Bhandari, W. Pascale, S. Sprague, V. Pascale. - In: THE KNEE. - ISSN 0968-0160. - 19:1(2012 Jan), pp. 8-13.

The Genesis II in primary total knee replacement : A systematic literature review of clinical outcomes

V. Pascale
Ultimo
2012

Abstract

Since its introduction in 1996, the Genesis II Total Knee System has produced good clinical results in patients undergoing primary total knee replacement. A systematic review of the literature–the first of its kind for this device–was undertaken to collect data on the Genesis II in order to provide a better understanding of its medium- to long-term performance. Of 124 Genesis II-related studies published in the literature, 11 met the eligibility criteria and were included in the final analysis. The included studies had a mean follow-up length of 38.1 months. Data from 1201 knees were available for review. Patients were an average of 70.5 years of age and predominantly female (63%). Findings indicated that the revision rate with this implant is low with up to 11.9 years of follow-up, with 14 revisions in total. The survival rate ranged from 100% at 1 and 2 years to 96.0% at 11.9 years. The mean Knee Society knee score improved 51.0 points from preoperative to postoperative evaluation. In conclusion, the Genesis II exhibited good clinical performance with up to 11 years follow-up, with an encouraging rate of survival and improvement in function. Additional studies with larger sample sizes and longer follow-up periods are needed to better understand the long-term performance of this implant.
Genesis II ; Systematic review ; Total knee replacement ; Total knee arthroplasty ; Implant survival
Settore MED/33 - Malattie Apparato Locomotore
gen-2012
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/171536
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 21
  • ???jsp.display-item.citation.isi??? 16
social impact