The aortic root functional unit (ARFU) is a complex structure whose functions are strictly dependent on the biomechanical interaction among each of its anatomically defined elements. The classical approach to the in vitro study of aortic hydrodynamics does not take this complexity into account. We propose a novel methodology based on the possibility to house whole natural ARFU samples in a purposely designed pulsatile mock loop, allowing for aortic surgery simulation. To point out the usability and potentialities of the device, the mock loop was tested with untreated porcine ARFU samples and with one ARFU prosthesized with a state-of-the-art bioprosthesis. The sample holder design was proved to allow the clinician to house and treat the ARFU sample in the mock loop with easiness and repeatability. The valve leakage with the prosthesized ARFU was comparable with literature data, and Effective orifice areas were consistent with the constructor's data. In contrast, the recorded pressure drops exceeded the data from the manufacturer and were quite aligned with in vivo postop echo-Doppler data acquired in implant recipients. This result suggests that our apparatus and methodology provide a way to investigate aortic hydrodynamic phenomena that resemble in a close way to those taking place in the final recipients' circulation.

A novel approach to the in vitro hydrodynamic study of the aortic valve : mock loop development and test / R. Vismara, G.B. Fiore, A. Mangini, M. Contino, M. Lemma, A. Redaelli, C. Antona. - In: ASAIO JOURNAL. - ISSN 1058-2916. - 56:4(2010), pp. 279-284.

A novel approach to the in vitro hydrodynamic study of the aortic valve : mock loop development and test

M. Contino;C. Antona
Ultimo
2010

Abstract

The aortic root functional unit (ARFU) is a complex structure whose functions are strictly dependent on the biomechanical interaction among each of its anatomically defined elements. The classical approach to the in vitro study of aortic hydrodynamics does not take this complexity into account. We propose a novel methodology based on the possibility to house whole natural ARFU samples in a purposely designed pulsatile mock loop, allowing for aortic surgery simulation. To point out the usability and potentialities of the device, the mock loop was tested with untreated porcine ARFU samples and with one ARFU prosthesized with a state-of-the-art bioprosthesis. The sample holder design was proved to allow the clinician to house and treat the ARFU sample in the mock loop with easiness and repeatability. The valve leakage with the prosthesized ARFU was comparable with literature data, and Effective orifice areas were consistent with the constructor's data. In contrast, the recorded pressure drops exceeded the data from the manufacturer and were quite aligned with in vivo postop echo-Doppler data acquired in implant recipients. This result suggests that our apparatus and methodology provide a way to investigate aortic hydrodynamic phenomena that resemble in a close way to those taking place in the final recipients' circulation.
Settore MED/23 - Chirurgia Cardiaca
Settore ING-IND/34 - Bioingegneria Industriale
2010
Article (author)
File in questo prodotto:
File Dimensione Formato  
Vismara et al. - 2010 - A Novel Approach to the In Vitro Hydrodynamic Study of the Aortic Valve Mock Loop Development and Test.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 627.17 kB
Formato Adobe PDF
627.17 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/170928
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 29
  • ???jsp.display-item.citation.isi??? 28
social impact