Recently, the neo-chordae technique (NCT) was proposed to stabilize the surgical correction of isolated aortic valve (AV) prolapse. Neo-chordae are inserted into the corrected leaflet to drive its closure by minimal tensions and prevent relapses. In a previous in vitro study we analysed the NCT effects on healthy aortic roots (ARs). Here we extend that analysis via finite element models (FEMs). After successfully replicating the experimental conditions for validation purposes, we modified our AR FEM, obtaining a continent AV with minor isolated prolapse, thus representing a realistic clinical scenario. We then simulated the NCT, and systematically assessed the acute effects of changing neo-chordae length, opening angle, asymmetry and insertion on the aorta. In the baseline configuration the NCT restored physiological AV dynamics and coaptation, without inducing abnormal leaflet stresses. This outcome was notably sensitive only to neo-chordae length, suggesting that the NCT is a potentially easy-to-standardize technique. However, this parameter is crucial: major shortenings (6 mm) prevent coaptation and increase leaflet stresses by 359 kPa, beyond the yield limit. Minor shortenings (2-4 mm) only induce a negligible stress increase and mild leaflet tethering, which however may hamper the long-term surgical outcome.

Aortic valve repair via neo-chordae technique : mechanistic insight through numerical modelling / E. Votta, L. Paroni, C.A. Conti, A. Pelosi, A. Mangini, P. D'Alesio, R. Vismara, C. Antona, A. Redaelli. - In: ANNALS OF BIOMEDICAL ENGINEERING. - ISSN 0090-6964. - 40:5(2012 May), pp. 1039-1051. [10.1007/s10439-011-0497-9]

Aortic valve repair via neo-chordae technique : mechanistic insight through numerical modelling

C. Antona
Penultimo
;
2012

Abstract

Recently, the neo-chordae technique (NCT) was proposed to stabilize the surgical correction of isolated aortic valve (AV) prolapse. Neo-chordae are inserted into the corrected leaflet to drive its closure by minimal tensions and prevent relapses. In a previous in vitro study we analysed the NCT effects on healthy aortic roots (ARs). Here we extend that analysis via finite element models (FEMs). After successfully replicating the experimental conditions for validation purposes, we modified our AR FEM, obtaining a continent AV with minor isolated prolapse, thus representing a realistic clinical scenario. We then simulated the NCT, and systematically assessed the acute effects of changing neo-chordae length, opening angle, asymmetry and insertion on the aorta. In the baseline configuration the NCT restored physiological AV dynamics and coaptation, without inducing abnormal leaflet stresses. This outcome was notably sensitive only to neo-chordae length, suggesting that the NCT is a potentially easy-to-standardize technique. However, this parameter is crucial: major shortenings (6 mm) prevent coaptation and increase leaflet stresses by 359 kPa, beyond the yield limit. Minor shortenings (2-4 mm) only induce a negligible stress increase and mild leaflet tethering, which however may hamper the long-term surgical outcome.
aortic valve; EPTFE chordae; finite element modeling; surgical correction
Settore MED/23 - Chirurgia Cardiaca
Settore ING-IND/34 - Bioingegneria Industriale
mag-2012
Article (author)
File in questo prodotto:
File Dimensione Formato  
art%3A10.1007%2Fs10439-011-0497-9.pdf

accesso riservato

Tipologia: Publisher's version/PDF
Dimensione 1.15 MB
Formato Adobe PDF
1.15 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/170878
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact