We have realized a mixed continuous-pulsed reset preamplifier suitable for multi-channel gamma-ray sensors. The continuous-reset mode is used for typical signal amplitudes within the ADC input range, or 1 V. The pulsed-reset mode works on larger signal amplitudes, either caused by individual events or by bursts of piled-up events. Such operation mode maximizes the live time in the typical energy range and minimizes the dead time caused by ADC saturation on large individual signals or at high count rates. The amplitude of large individual signals can also be estimated from the reset time still achieving a high resolution. Using this technique and a bulky High Purity Germanium detector we got a "continuous-reset" range of 2 MeV with a resolution of 2.02 keV fwhm at 1.408 MeV, and an extended "pulsed-reset" range of 27 MeV, with a typical resolution of 0.3% at 27 MeV.

A Mixed Continuous-Pulsed Reset Technique for Digitized Preamplifiers of Radiation Signals / F. Zocca, A. Pullia, C. Boiano, R. Bassini - In: Nuclear Science Symposium Conference Record / Yu Bo. - [s.l] : IEEE, 2005. - ISBN 0-7803-9221-3. - pp. 382-386 (( convegno Nuclear Science Symposium tenutosi a Puerto Rico nel 2005 [10.1109/NSSMIC.2005.1596275].

A Mixed Continuous-Pulsed Reset Technique for Digitized Preamplifiers of Radiation Signals

F. Zocca
Primo
;
A. Pullia
Secondo
;
2005

Abstract

We have realized a mixed continuous-pulsed reset preamplifier suitable for multi-channel gamma-ray sensors. The continuous-reset mode is used for typical signal amplitudes within the ADC input range, or 1 V. The pulsed-reset mode works on larger signal amplitudes, either caused by individual events or by bursts of piled-up events. Such operation mode maximizes the live time in the typical energy range and minimizes the dead time caused by ADC saturation on large individual signals or at high count rates. The amplitude of large individual signals can also be estimated from the reset time still achieving a high resolution. Using this technique and a bulky High Purity Germanium detector we got a "continuous-reset" range of 2 MeV with a resolution of 2.02 keV fwhm at 1.408 MeV, and an extended "pulsed-reset" range of 27 MeV, with a typical resolution of 0.3% at 27 MeV.
Settore ING-INF/01 - Elettronica
2005
Book Part (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/16608
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact