A collimated epithermal beam for boron neutron capture therapy (BNCT) research has been designed and built at the TAPIRO fast research reactor. A complete experimental characterisation of the radiation field in the irradiation chamber has been performed, to verify agreement with IAEA requirements. Slow neutron fluxes have been measured by means of an activation technique and with thermoluminescent detectors (TLDs). The fast neutron dose has been determined with gel dosemeters, while the fast neutron spectrum has been acquired by means of a neutron spectrometer based on superheated drop detectors. The gamma-dose has been measured with gel dosemeters and TLDs. For an independent verification of the experimental results, fluxes, doses and neutron spectra have been calculated with Monte Carlo simulations using the codes MCNP4B and MCNPX_2.1.5 with the direct statistical approach (DSA). The results obtained confirm that the epithermal beams achievable at TAPIRO are of suitable quality for BNCT purposes.

Characterisation of the TAPIRO BNCT epithermal facility / K.W. Burn, V. Colli, G. Curzio, F. d'Errico, G. Gambarini, G. Rosi, L.Scolari. - In: RADIATION PROTECTION DOSIMETRY. - ISSN 0144-8420. - 110:1-4(2004), pp. 645-649. [10.1093/rpd/nch161]

Characterisation of the TAPIRO BNCT epithermal facility

V. Colli
Secondo
;
G. Gambarini;
2004

Abstract

A collimated epithermal beam for boron neutron capture therapy (BNCT) research has been designed and built at the TAPIRO fast research reactor. A complete experimental characterisation of the radiation field in the irradiation chamber has been performed, to verify agreement with IAEA requirements. Slow neutron fluxes have been measured by means of an activation technique and with thermoluminescent detectors (TLDs). The fast neutron dose has been determined with gel dosemeters, while the fast neutron spectrum has been acquired by means of a neutron spectrometer based on superheated drop detectors. The gamma-dose has been measured with gel dosemeters and TLDs. For an independent verification of the experimental results, fluxes, doses and neutron spectra have been calculated with Monte Carlo simulations using the codes MCNP4B and MCNPX_2.1.5 with the direct statistical approach (DSA). The results obtained confirm that the epithermal beams achievable at TAPIRO are of suitable quality for BNCT purposes.
English
dosimetry; fission reactor monitoring; fission research reactors; gamma-ray detection; Monte Carlo methods; neutron capture therapy; neutron detection; neutron flux; neutron spectrometers; nuclear engineering computing; thermoluminescent dosimeters
Settore FIS/01 - Fisica Sperimentale
Articolo
Sì, ma tipo non specificato
2004
Oxford University Press
110
1-4
645
649
Periodico con rilevanza internazionale
info:eu-repo/semantics/article
Characterisation of the TAPIRO BNCT epithermal facility / K.W. Burn, V. Colli, G. Curzio, F. d'Errico, G. Gambarini, G. Rosi, L.Scolari. - In: RADIATION PROTECTION DOSIMETRY. - ISSN 0144-8420. - 110:1-4(2004), pp. 645-649. [10.1093/rpd/nch161]
none
Prodotti della ricerca::01 - Articolo su periodico
7
262
Article (author)
no
K.W. Burn, V. Colli, G. Curzio, F. D'Errico, G. Gambarini, G. Rosi, L. Scolari
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/16597
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 4
social impact