The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect to standard absorption imaging, in the specific case of micro-calcifications detection.

Theoretical considerations for X-ray phase contrast mammography by Thomson source / A. Cedola, I. Bukreeva, S. Lagomarsino, C. Maroli, V. Petrillo. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 608:1(2009), pp. S23-S27. [10.1016/j.nima.2009.05.044]

Theoretical considerations for X-ray phase contrast mammography by Thomson source

V. Petrillo
Ultimo
2009

Abstract

The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect to standard absorption imaging, in the specific case of micro-calcifications detection.
English
Mammography; Thomson source; X-ray phase contrast
Settore FIS/03 - Fisica della Materia
Articolo
Sì, ma tipo non specificato
2009
Elsevier
608
1
S23
S27
Periodico con rilevanza internazionale
info:eu-repo/semantics/article
Theoretical considerations for X-ray phase contrast mammography by Thomson source / A. Cedola, I. Bukreeva, S. Lagomarsino, C. Maroli, V. Petrillo. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 608:1(2009), pp. S23-S27. [10.1016/j.nima.2009.05.044]
none
Prodotti della ricerca::01 - Articolo su periodico
5
262
Article (author)
Periodico con Impact Factor
A. Cedola, I. Bukreeva, S. Lagomarsino, C. Maroli, V. Petrillo
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/151898
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact