Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
IRIS Institutional Research Information System - AIR Archivio Istituzionale della Ricerca
The feasibility of measuring g -factors using the TDPAD method applied to high-energy, heavy fragmentation products is explored. The 2623keV isomer in 192Pb with = 1.57 μs has been produced using the fragmentation of a 1A GeV 238U beam. The results presented demonstrate for the first time that such heavy nuclei produced in a fragmentation reaction with a relativistic beam are sufficiently well spin-aligned. Moreover, the rather large value of the alignment, 28(10)% of the maximum possible, is preserved during the separation process allowing the determination of magnetic moments. The measured values of the lifetime, = 1.54(9) μs, and the g -factor, g = - 0.175(20) , agree with the results of previous investigations using fusion-evaporation reactions.
Spin-alignment and g-factor measurement of the Ipi= 12+ isomer in 192Pb produced in the relativistic-energy fragmentation of a 238U beam / M. Kmiecik, A. Maj, J. Gerl, G. Neyens, L. Atanasova, D.L. Balabanski, F. Becker, P. Bednarczyk, G. Benzoni, N. Blasi, A. Bracco, S. Brambilla, L. Caceres, F. Camera, M. Ciemala, F.C.L. Crespi, S.K. Chamoli, S. Chmel, J.M. Daugas, P. Detistov, P. Doornenbal, G. Georgiev, K. Gladnishki, M. Gorska, H. Grawe, J. Grebosz, M. Hass, R. Hoischen, G. Ilie, M. Ionescu-Bujor, J. Jolie, I. Kojuharov, A. Krasznahorkay, R. Kulessa,M. Lach, S. Lakshmi, S. Leoni, G. Lo Bianco, R. Lozeva, K.H. Maier, S. Mallion, K. Mazurek, W. Meczynski, B. Million, D. Montanari, S. Myalski, C. Petrache, M. Pfutzner, S. Pietri, Zs. Podolyak, W. Prokopowicz, D. Rudolph, N. Saito, T.R. Saito, A. Saltarelli, G.S. Simpson, J. Styczen, N. Vermeulen, E. Werner-Malento, O. Wieland, H.J. Wollersheim, M. Zieblinski. - In: THE EUROPEAN PHYSICAL JOURNAL. A, HADRONS AND NUCLEI. - ISSN 1434-6001. - 45:2(2010), pp. 153-158. [10.1140/epja/i2010-11003-4]
Spin-alignment and g-factor measurement of the Ipi= 12+ isomer in 192Pb produced in the relativistic-energy fragmentation of a 238U beam
M. Kmiecik;A. Maj;J. Gerl;G. Neyens;L. Atanasova;D. L. Balabanski;F. Becker;P. Bednarczyk;G. Benzoni;N. Blasi;A. Bracco;S. Brambilla;L. Caceres;F. Camera;M. Ciemala;F.C.L. Crespi;S. K. Chamoli;S. Chmel;J. M. Daugas;P. Detistov;P. Doornenbal;G. Georgiev;K. Gladnishki;M. Gorska;H. Grawe;J. Grebosz;M. Hass;R. Hoischen;G. Ilie;M. Ionescu Bujor;J. Jolie;I. Kojuharov;A. Krasznahorkay;R. Kulessa;M. Lach;S. Lakshmi;S. Leoni;G. Lo Bianco;R. Lozeva;K. H. Maier;S. Mallion;K. Mazurek;W. Meczynski;B. Million;D. Montanari;S. Myalski;C. Petrache;M. Pfutzner;S. Pietri;Z.s. Podolyak;W. Prokopowicz;D. Rudolph;N. Saito;T. R. Saito;A. Saltarelli;G. S. Simpson;J. Styczen;N. Vermeulen;E. Werner Malento;O. Wieland;H. J. Wollersheim;M. Zieblinski
2010
Abstract
The feasibility of measuring g -factors using the TDPAD method applied to high-energy, heavy fragmentation products is explored. The 2623keV isomer in 192Pb with = 1.57 μs has been produced using the fragmentation of a 1A GeV 238U beam. The results presented demonstrate for the first time that such heavy nuclei produced in a fragmentation reaction with a relativistic beam are sufficiently well spin-aligned. Moreover, the rather large value of the alignment, 28(10)% of the maximum possible, is preserved during the separation process allowing the determination of magnetic moments. The measured values of the lifetime, = 1.54(9) μs, and the g -factor, g = - 0.175(20) , agree with the results of previous investigations using fusion-evaporation reactions.
Spin-alignment and g-factor measurement of the Ipi= 12+ isomer in 192Pb produced in the relativistic-energy fragmentation of a 238U beam / M. Kmiecik, A. Maj, J. Gerl, G. Neyens, L. Atanasova, D.L. Balabanski, F. Becker, P. Bednarczyk, G. Benzoni, N. Blasi, A. Bracco, S. Brambilla, L. Caceres, F. Camera, M. Ciemala, F.C.L. Crespi, S.K. Chamoli, S. Chmel, J.M. Daugas, P. Detistov, P. Doornenbal, G. Georgiev, K. Gladnishki, M. Gorska, H. Grawe, J. Grebosz, M. Hass, R. Hoischen, G. Ilie, M. Ionescu-Bujor, J. Jolie, I. Kojuharov, A. Krasznahorkay, R. Kulessa,M. Lach, S. Lakshmi, S. Leoni, G. Lo Bianco, R. Lozeva, K.H. Maier, S. Mallion, K. Mazurek, W. Meczynski, B. Million, D. Montanari, S. Myalski, C. Petrache, M. Pfutzner, S. Pietri, Zs. Podolyak, W. Prokopowicz, D. Rudolph, N. Saito, T.R. Saito, A. Saltarelli, G.S. Simpson, J. Styczen, N. Vermeulen, E. Werner-Malento, O. Wieland, H.J. Wollersheim, M. Zieblinski. - In: THE EUROPEAN PHYSICAL JOURNAL. A, HADRONS AND NUCLEI. - ISSN 1434-6001. - 45:2(2010), pp. 153-158. [10.1140/epja/i2010-11003-4]
none
Prodotti della ricerca::01 - Articolo su periodico
62
262
Article (author)
no
M. Kmiecik, A. Maj, J. Gerl, G. Neyens, L. Atanasova, D.L. Balabanski, F. Becker, P. Bednarczyk, G. Benzoni, N. Blasi, A. Bracco, S. Brambilla, L. Caceres, F. Camera, M. Ciemala, F.C.L. Crespi, S.K. Chamoli, S. Chmel, J.M. Daugas, P. Detistov, P. Doornenbal, G. Georgiev, K. Gladnishki, M. Gorska, H. Grawe, J. Grebosz, M. Hass, R. Hoischen, G. Ilie, M. Ionescu Bujor, J. Jolie, I. Kojuharov, A. Krasznahorkay, R. Kulessa, M. Lach, S. Lakshmi, S. Leoni, G. Lo Bianco, R. Lozeva, K.H. Maier, S. Mallion, K. Mazurek, W. Meczynski, B. Million, D. Montanari, S. Myalski, C. Petrache, M. Pfutzner, S. Pietri, Z.S. Podolyak, W. Prokopowicz, D. Rudolph, N. Saito, T.R. Saito, A. Saltarelli, G.S. Simpson, J. Styczen, N. Vermeulen, E. Werner Malento, O. Wieland, H.J. Wollersheim, M. Zieblinski
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/150441
Citazioni
ND
8
8
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.