PURPOSE: To test the accuracy and reproducibility of a 3-dimensional (3D) stereophotogrammetric imaging system for measuring the facial soft tissues of healthy subjects. MATERIALS AND METHODS: Three-dimensional soft tissue facial landmarks were obtained from the faces of 10 adult subjects, by use of a 3D stereophotogrammetric imaging system (Vectra; Canfield Scientific, Fairfield, NJ). Sixteen linear measurements were computed. Systematic and random errors between operators, calibration steps, and acquisitions were calculated. RESULTS: No systematic errors were found for all performed tests (P > .05, paired t test). The method was repeatable, and random errors were always lower than 1 mm, except for the distance from cheilion to cheilion. Repeated sets of acquisition showed random errors up to 0.91 mm, without systematic biases. CONCLUSION: The 3D stereophotogrammetric imaging system can assess the coordinates of facial landmarks with good precision and reproducibility. The method is fast and can obtain facial measurements with few errors.

Accuracy and Reproducibility of a 3-Dimensional Stereophotogrammetric Imaging System / M. De Menezes, R. Rosati, V.F. Ferrario, C. Sforza. - In: JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY. - ISSN 0278-2391. - 68:9(2010), pp. 2129-2135. [10.1016/j.joms.2009.09.036]

Accuracy and Reproducibility of a 3-Dimensional Stereophotogrammetric Imaging System

M. De Menezes
Primo
;
R. Rosati
Secondo
;
V.F. Ferrario
Penultimo
;
C. Sforza
Ultimo
2010

Abstract

PURPOSE: To test the accuracy and reproducibility of a 3-dimensional (3D) stereophotogrammetric imaging system for measuring the facial soft tissues of healthy subjects. MATERIALS AND METHODS: Three-dimensional soft tissue facial landmarks were obtained from the faces of 10 adult subjects, by use of a 3D stereophotogrammetric imaging system (Vectra; Canfield Scientific, Fairfield, NJ). Sixteen linear measurements were computed. Systematic and random errors between operators, calibration steps, and acquisitions were calculated. RESULTS: No systematic errors were found for all performed tests (P > .05, paired t test). The method was repeatable, and random errors were always lower than 1 mm, except for the distance from cheilion to cheilion. Repeated sets of acquisition showed random errors up to 0.91 mm, without systematic biases. CONCLUSION: The 3D stereophotogrammetric imaging system can assess the coordinates of facial landmarks with good precision and reproducibility. The method is fast and can obtain facial measurements with few errors.
English
Settore BIO/16 - Anatomia Umana
Articolo
Esperti anonimi
2010
Saunders
68
9
2129
2135
Periodico con rilevanza internazionale
info:eu-repo/semantics/article
Accuracy and Reproducibility of a 3-Dimensional Stereophotogrammetric Imaging System / M. De Menezes, R. Rosati, V.F. Ferrario, C. Sforza. - In: JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY. - ISSN 0278-2391. - 68:9(2010), pp. 2129-2135. [10.1016/j.joms.2009.09.036]
none
Prodotti della ricerca::01 - Articolo su periodico
4
262
Article (author)
si
M. De Menezes, R. Rosati, V.F. Ferrario, C. Sforza
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/146552
Citazioni
  • ???jsp.display-item.citation.pmc??? 60
  • Scopus 186
  • ???jsp.display-item.citation.isi??? 168
  • OpenAlex ND
social impact