This multicenter study evaluated the performance of an improved Elecsys Troponin T (cTnT) immunoassay with a special focus on the serum to heparin-plasma comparability. The evaluation was performed in 10 laboratories according to a standardized protocol (Roche Diagnostics, study no. B05P008). The cTnT assay was performed on Modular E170 and Elecsys 2010 systems. The cTnI immunoassays (Vidas® Biomerieux; Dimension® Dade Behring; Immulite® 2000 DPC) were performed according to the manufacturer’s instructions. Intraassay (n=21) and interassay (2 runs/d, 10d, triplicate measurements) imprecisions were evaluated using two commercial controls and 6 serum pools (cTnT, 0.014 to 4.102 μg/L). Intraassay CVs ranged from 0.7% to 3.2%. Interassay CVs ranged from 3.6% to 35.4% (cTnT <0.10 μg/L) and 1.8% to 9.1% (cTnT >0.10 μg/L), respectively. The cutoff for myocardial necrosis was determined to be 0.028 μg/L using the 10% interassay CV criteria. Linearity was assessed by serial dilutions of 5 serum samples using cTnT negative pools. Linearity was proven up to 21.3 μg/L (recoveries: 90-110%). The comparison between the 4th generation and the commercially available cTnT assay showed highly similar results across the whole measuring range: y=1.02x-0.001, r=0.998; n=988. Using the commercial cTnT reagent, the serum to heparin-plasma comparison yielded a systematic bias to ~10% lower cTnT results in heparin-plasma. Suitable comparability was obtained using the 4th generation assay. The regression analysis (serum vs. heparin) across the studied range (0.01 to 16 μg/L) yielded the following equation: y=0.993x-0.001; r=0.986; n=441. The regression data were comparable to the serum/heparinplasma comparability of the studied cTnI immunoassays (slopes: 0.939-1.241; intercepts: 0.015-0.054, r: 0.981- 0.998, n: 33-49). However, individual serum to matched heparin-plasma samples still yielded poor comparability (bias >20%) using the 4th generation cTnT as well as cTnI assays. Our data show an excellent analytical performance of the improved cTnT mmunoassay, with no systematic bias between serum and heparin-plasma cTnT results. Further studies are necessary to investigate the cause of poor comparability of troponin results in rare individual serum to matched heparin-plasma samples.

Results from a multicenter evaluation of the 4th generation Elecsys troponin T assay / F. Pagani, F. Apple, L. Garcia Beltran, D. Hermsen, A. Jaffe, B. Karon, E. Lewandrowski, A. Muhlbacher, R. Muller, J. Ordonez, T. Plecko, J. Jarausch, M. Panteghini. - In: BIOCHIMICA CLINICA. - ISSN 0393-0564. - 30:4(2006), pp. 358-358. ((Intervento presentato al 38. convegno Congresso nazionale della Società Italiana di Biochimica Clinica e Biologia Molecolare Clinica, tenutosi a Torino nel 2006.

Results from a multicenter evaluation of the 4th generation Elecsys troponin T assay

M. Panteghini
2006

Abstract

This multicenter study evaluated the performance of an improved Elecsys Troponin T (cTnT) immunoassay with a special focus on the serum to heparin-plasma comparability. The evaluation was performed in 10 laboratories according to a standardized protocol (Roche Diagnostics, study no. B05P008). The cTnT assay was performed on Modular E170 and Elecsys 2010 systems. The cTnI immunoassays (Vidas® Biomerieux; Dimension® Dade Behring; Immulite® 2000 DPC) were performed according to the manufacturer’s instructions. Intraassay (n=21) and interassay (2 runs/d, 10d, triplicate measurements) imprecisions were evaluated using two commercial controls and 6 serum pools (cTnT, 0.014 to 4.102 μg/L). Intraassay CVs ranged from 0.7% to 3.2%. Interassay CVs ranged from 3.6% to 35.4% (cTnT <0.10 μg/L) and 1.8% to 9.1% (cTnT >0.10 μg/L), respectively. The cutoff for myocardial necrosis was determined to be 0.028 μg/L using the 10% interassay CV criteria. Linearity was assessed by serial dilutions of 5 serum samples using cTnT negative pools. Linearity was proven up to 21.3 μg/L (recoveries: 90-110%). The comparison between the 4th generation and the commercially available cTnT assay showed highly similar results across the whole measuring range: y=1.02x-0.001, r=0.998; n=988. Using the commercial cTnT reagent, the serum to heparin-plasma comparison yielded a systematic bias to ~10% lower cTnT results in heparin-plasma. Suitable comparability was obtained using the 4th generation assay. The regression analysis (serum vs. heparin) across the studied range (0.01 to 16 μg/L) yielded the following equation: y=0.993x-0.001; r=0.986; n=441. The regression data were comparable to the serum/heparinplasma comparability of the studied cTnI immunoassays (slopes: 0.939-1.241; intercepts: 0.015-0.054, r: 0.981- 0.998, n: 33-49). However, individual serum to matched heparin-plasma samples still yielded poor comparability (bias >20%) using the 4th generation cTnT as well as cTnI assays. Our data show an excellent analytical performance of the improved cTnT mmunoassay, with no systematic bias between serum and heparin-plasma cTnT results. Further studies are necessary to investigate the cause of poor comparability of troponin results in rare individual serum to matched heparin-plasma samples.
English
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
Poster
Sì, ma tipo non specificato
2006
Biomedia
30
4
358
358
Periodico con rilevanza nazionale
Congresso nazionale della Società Italiana di Biochimica Clinica e Biologia Molecolare Clinica,
Torino
2006
38
SIBioC Società Italiana di Biochimica Clinica e Biologia Molecolare Clinica
Convegno nazionale
Intervento richiesto
info:eu-repo/semantics/article
Results from a multicenter evaluation of the 4th generation Elecsys troponin T assay / F. Pagani, F. Apple, L. Garcia Beltran, D. Hermsen, A. Jaffe, B. Karon, E. Lewandrowski, A. Muhlbacher, R. Muller, J. Ordonez, T. Plecko, J. Jarausch, M. Panteghini. - In: BIOCHIMICA CLINICA. - ISSN 0393-0564. - 30:4(2006), pp. 358-358. ((Intervento presentato al 38. convegno Congresso nazionale della Società Italiana di Biochimica Clinica e Biologia Molecolare Clinica, tenutosi a Torino nel 2006.
none
Prodotti della ricerca::01 - Articolo su periodico
13
275
Article (author)
no
F. Pagani, F. Apple, L. Garcia Beltran, D. Hermsen, A. Jaffe, B. Karon, E. Lewandrowski, A. Muhlbacher, R. Muller, J. Ordonez, T. Plecko, J. Jarausch,...espandi
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/145489
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact