A novel focused ion beam-based technique is presented for the read-out of microradiographs of Caenorhabditis elegans nematodes generated by soft x-ray contact microscopy (SXCM). In previous studies, the read-out was performed by atomic force microscopy (AFM), but in our work SXCM microradiographs were imaged by scanning ion microscopy (SIM) in a focused ion beam/scanning electron microscope (FIB/SEM). It allows an ad libitum selection of a sample region for gross morphologic to nanometric investigations, with a sequence of imaging and cutting. The FIB/SEM is less sensitive to height variation of the relief, and sectioning makes it possible to analyse the sample further. The SXCM can be coupled to SIM in a more efficient and faster way than to AFM. Scanning ion microscopy is the method of choice for the read-out of microradiographs of small multicellular organisms.

Read-out of soft X-ray contact microscopy microradiographs by focused ion beam/scanning electron microscope / M. Milani, D. Drobne, F. Tatti, D. Batani, G. Poletti, F. Orsini, A. Zullini, A. Zrimec. - In: SCANNING. - ISSN 0161-0457. - 27:5(2005), pp. 249-253.

Read-out of soft X-ray contact microscopy microradiographs by focused ion beam/scanning electron microscope

G. Poletti;F. Orsini;
2005

Abstract

A novel focused ion beam-based technique is presented for the read-out of microradiographs of Caenorhabditis elegans nematodes generated by soft x-ray contact microscopy (SXCM). In previous studies, the read-out was performed by atomic force microscopy (AFM), but in our work SXCM microradiographs were imaged by scanning ion microscopy (SIM) in a focused ion beam/scanning electron microscope (FIB/SEM). It allows an ad libitum selection of a sample region for gross morphologic to nanometric investigations, with a sequence of imaging and cutting. The FIB/SEM is less sensitive to height variation of the relief, and sectioning makes it possible to analyse the sample further. The SXCM can be coupled to SIM in a more efficient and faster way than to AFM. Scanning ion microscopy is the method of choice for the read-out of microradiographs of small multicellular organisms.
English
Atomic force microscopy; Caenorhabditis elegans; Focused ion beam; Soft x-ray microscopy; Ultramicroscopy
Settore FIS/01 - Fisica Sperimentale
Articolo
Sì, ma tipo non specificato
2005
FAMS
27
5
249
253
Periodico con rilevanza internazionale
ISI:000232623300004
info:eu-repo/semantics/article
Read-out of soft X-ray contact microscopy microradiographs by focused ion beam/scanning electron microscope / M. Milani, D. Drobne, F. Tatti, D. Batani, G. Poletti, F. Orsini, A. Zullini, A. Zrimec. - In: SCANNING. - ISSN 0161-0457. - 27:5(2005), pp. 249-253.
none
Prodotti della ricerca::01 - Articolo su periodico
8
262
Article (author)
Periodico con Impact Factor
M. Milani, D. Drobne, F. Tatti, D. Batani, G. Poletti, F. Orsini, A. Zullini, A. Zrimec
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/14207
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 6
  • ???jsp.display-item.citation.isi??? ND
social impact