Together with serum ferritin, erythrocyte ferritincan be a valuable diagnostic tool for evaluating the degree of impaired iron metabolism in different diseases. We collected peripheral blood samples from 64 subjects (22 healthy volunteers, 20 patients with hereditary hemochromatosis, and 22 patients on regular hemodialysis with secondary anemia) to evaluate whether an immunoenzymatic method generally used for serum ferritin can also be used to determine erythrocyte ferritin levels under various conditions of body iron status. Serum and erythrocyte ferritin levels were assayed in parallel using a microparticle enzyme immunoassay (MEIA) IMx-Ferritin kit and an IMx analyzer. The inter-assay imprecision of the serum and erythrocyte ferritin assays was 4.9% and 5.05%, the intra-assay imprecision was 2.2% and 2.3%, and the mean recovery was 102% (range 96-105%) and 101% (range 99-105%), respectively. Both serum and erythrocyte ferritin assays showed a detection limit of 1 microg/L and good linearity (R(2) = 0.99) in the intervals 13.9-443 and 3.9-135.6 microg/L, respectively. Our findings demonstrate that the IMx-Ferritin assay currently used to measure serum ferritin levels can also be adopted to measure erythrocyte ferritin insofar as it clearly discriminates high and low erythrocyte ferritin levels in cases of both iron overload and deficiency.

Erythocyte ferritin concentration : analytical performance of the immunoenzymatic IMx-Ferritin (Abbott) assay / C. Novembrino, A. Porcella, D. Conte, A.F. De Vecchi, G. Buccianti, S. Lonati, L. Duca, A.S.A. Ciani, F. Bamonti. - In: CLINICAL CHEMISTRY AND LABORATORY MEDICINE. - ISSN 1434-6621. - 43:4(2005), pp. 449-453. [10.1515/CCLM.2005.079]

Erythocyte ferritin concentration : analytical performance of the immunoenzymatic IMx-Ferritin (Abbott) assay

C. Novembrino
Primo
;
D. Conte;S. Lonati;L. Duca;A.S.A. Ciani
Penultimo
;
F. Bamonti
Ultimo
2005

Abstract

Together with serum ferritin, erythrocyte ferritincan be a valuable diagnostic tool for evaluating the degree of impaired iron metabolism in different diseases. We collected peripheral blood samples from 64 subjects (22 healthy volunteers, 20 patients with hereditary hemochromatosis, and 22 patients on regular hemodialysis with secondary anemia) to evaluate whether an immunoenzymatic method generally used for serum ferritin can also be used to determine erythrocyte ferritin levels under various conditions of body iron status. Serum and erythrocyte ferritin levels were assayed in parallel using a microparticle enzyme immunoassay (MEIA) IMx-Ferritin kit and an IMx analyzer. The inter-assay imprecision of the serum and erythrocyte ferritin assays was 4.9% and 5.05%, the intra-assay imprecision was 2.2% and 2.3%, and the mean recovery was 102% (range 96-105%) and 101% (range 99-105%), respectively. Both serum and erythrocyte ferritin assays showed a detection limit of 1 microg/L and good linearity (R(2) = 0.99) in the intervals 13.9-443 and 3.9-135.6 microg/L, respectively. Our findings demonstrate that the IMx-Ferritin assay currently used to measure serum ferritin levels can also be adopted to measure erythrocyte ferritin insofar as it clearly discriminates high and low erythrocyte ferritin levels in cases of both iron overload and deficiency.
Analytical performance; Erythrocyte ferritin; Iron disorders; Microparticle enzyme immunoassay (MEIA); Serum ferritin
Settore MED/15 - Malattie del Sangue
Settore MED/12 - Gastroenterologia
Settore BIO/12 - Biochimica Clinica e Biologia Molecolare Clinica
2005
Article (author)
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/13300
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 7
social impact