A new approach, based on the use of atmospheric pressure chemical ionization ion trap mass spectrometry (APCI-ITMS), but without a corona discharge, was investigated for application to creating and monitoring protein ions. It must be emphasized that APCI is not usually used in protein analysis. In order to verify the applicability of the proposed method to the analysis of proteins, two standard proteins (horse cytochrome c and horse myoglobin) were analyzed. A mixture of the two proteins was also analyzed showing that this novel approach, based on the use of APCI, can be used in the analysis of protein mixtures.

Analysis of protein ions in the range 3000-12000 Th under partial (no discharge) atmospheric pressure chemical ionization conditions using ion trap mass spectrometry / S. Cristoni, L. Rossi Bernardi, I. Biunno, F. Guidugli. - In: RAPID COMMUNICATIONS IN MASS SPECTROMETRY. - ISSN 0951-4198. - 16:12(2002), pp. 1153-1159.

Analysis of protein ions in the range 3000-12000 Th under partial (no discharge) atmospheric pressure chemical ionization conditions using ion trap mass spectrometry

L. Rossi Bernardi;
2002

Abstract

A new approach, based on the use of atmospheric pressure chemical ionization ion trap mass spectrometry (APCI-ITMS), but without a corona discharge, was investigated for application to creating and monitoring protein ions. It must be emphasized that APCI is not usually used in protein analysis. In order to verify the applicability of the proposed method to the analysis of proteins, two standard proteins (horse cytochrome c and horse myoglobin) were analyzed. A mixture of the two proteins was also analyzed showing that this novel approach, based on the use of APCI, can be used in the analysis of protein mixtures.
English
Cytochrome c Group Ethylamines Myoglobin Solvents triethylamine
Settore BIO/10 - Biochimica
Articolo
Sì, ma tipo non specificato
2002
Heyden
16
12
1153
1159
Periodico con rilevanza internazionale
info:eu-repo/semantics/article
Analysis of protein ions in the range 3000-12000 Th under partial (no discharge) atmospheric pressure chemical ionization conditions using ion trap mass spectrometry / S. Cristoni, L. Rossi Bernardi, I. Biunno, F. Guidugli. - In: RAPID COMMUNICATIONS IN MASS SPECTROMETRY. - ISSN 0951-4198. - 16:12(2002), pp. 1153-1159.
none
Prodotti della ricerca::01 - Articolo su periodico
4
262
Article (author)
si
S. Cristoni, L. Rossi Bernardi, I. Biunno, F. Guidugli
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/12810
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 25
social impact