Purpose: Residual stresses are intrinsic stresses present in arteries even in the absence of external loads or blood pressure. They originate during growth and remodeling and contribute to vascular mechanical equilibrium. Despite advances in computational methods, incorporating residual stresses into patient-specific vascular models remains challenging. Evidence regarding the influence of circumferential residual stresses on physiological loading in realistic anatomies is still limited. Methods: We combined in vitro imaging, mechanical testing, and finite element (FE) simulations to incorporate residual stresses into a pressurized porcine aorta model. Medical images were acquired in both pressurized and zero-stress states, the latter obtained after 2 h of longitudinal cutting. Locally measured mechanical properties from distinct aortic regions were used to define an orthotropic hyperelastic material response. Residual stresses were restored by simulating vessel closure under displacement-controlled boundary conditions with a tied contact interface. Stress distributions were then compared in FE pressurization simulations performed with and without residual stresses. Results: Residual stresses substantially influenced the predicted stress fields. They homogenized stress across the vessel thickness and reduced stress concentrations near the lumen. Moreover, lumen cross-sectional areas at 120 mmHg aligned more closely with experimental measurements when residual stresses were included. In contrast, neglecting residual stresses produced an average overestimation of lumen area by 4.84% and stress peaks up to 50% higher in the inner wall. Conclusion: This study highlights the importance of accounting for residual stresses in biomechanical vascular simulations. Incorporating them improves prediction accuracy and reduces artificial stress concentrations, which is crucial for patient-specific risk assessment and surgical planning.

The Effect Of Localized Circumferential Residual Stress On Pressurized Stress State Of CT Reconstructed Vessels: A Finite Element Study / V. Lissoni, M.S.. - In: ANNALS OF BIOMEDICAL ENGINEERING. - ISSN 0090-6964. - 54:10(2026 Oct), pp. 3490-3504. [10.1007/s10439-026-04085-x]

The Effect Of Localized Circumferential Residual Stress On Pressurized Stress State Of CT Reconstructed Vessels: A Finite Element Study

M. Di Giancamillo;J. Bassi;
2026

Abstract

Purpose: Residual stresses are intrinsic stresses present in arteries even in the absence of external loads or blood pressure. They originate during growth and remodeling and contribute to vascular mechanical equilibrium. Despite advances in computational methods, incorporating residual stresses into patient-specific vascular models remains challenging. Evidence regarding the influence of circumferential residual stresses on physiological loading in realistic anatomies is still limited. Methods: We combined in vitro imaging, mechanical testing, and finite element (FE) simulations to incorporate residual stresses into a pressurized porcine aorta model. Medical images were acquired in both pressurized and zero-stress states, the latter obtained after 2 h of longitudinal cutting. Locally measured mechanical properties from distinct aortic regions were used to define an orthotropic hyperelastic material response. Residual stresses were restored by simulating vessel closure under displacement-controlled boundary conditions with a tied contact interface. Stress distributions were then compared in FE pressurization simulations performed with and without residual stresses. Results: Residual stresses substantially influenced the predicted stress fields. They homogenized stress across the vessel thickness and reduced stress concentrations near the lumen. Moreover, lumen cross-sectional areas at 120 mmHg aligned more closely with experimental measurements when residual stresses were included. In contrast, neglecting residual stresses produced an average overestimation of lumen area by 4.84% and stress peaks up to 50% higher in the inner wall. Conclusion: This study highlights the importance of accounting for residual stresses in biomechanical vascular simulations. Incorporating them improves prediction accuracy and reduces artificial stress concentrations, which is crucial for patient-specific risk assessment and surgical planning.
Aorta; Finite element model; Mechanical properties; Residual stress; Segmentation
Settore MVET-05/A - Clinica chirurgica veterinaria
ott-2026
23-mar-2026
Article (author)
File in questo prodotto:
File Dimensione Formato  
unpaywall-bitstream-1636434595.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Licenza: Creative commons
Dimensione 2.04 MB
Formato Adobe PDF
2.04 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I metadati presenti in AIR sono rilasciati con licenza CCO mentre i file delle pubblicazioni sono rilasciati con licenza CC BY-SA, salvo diversa indicazione. In caso di violazione di copyright, contattare l'assistenza di AIR

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1276983
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
  • OpenAlex 1
social impact