Ground Source Heat Pump systems can significantly contribute to the decarbonization of the built environment but may incur high groundwork costs. Energy Geostructures (EGs) are alternative solutions that combine Heat Pumps with heat exchanger circuits embedded in ground structures, such as foundations and retaining walls, thus reducing installation costs. This paper reviews the state of the art of EGs and the recent advances by the Italian project GEOREFIT, specifically addressing the applicability and efficiency of this technology in energy retrofitting of existing buildings and infrastructures. The paper exemplifies technical solutions for EG installation in refurbishment projects and shows that EG energy performance is generally comparable and sometimes higher than conventional Ground Heat Exchangers.
Advancing Sustainable Climatization by Way of Energy Geostructures in the Retrofitting of Buildings / M. Barla, M.R.A. (LECTURE NOTES IN CIVIL ENGINEERING). - In: CLIMA 2025 Volume 3 / [a cura di] C. Zilio, F. Busato, L. Mazzarella, M. Noro. - [s.l] : Springer, 2026. - ISBN 9783032105455. - pp. 960-969 (( 15. REHVA HVAC World Congress, CLIMA 2025 : June, 4th - 6th Milano 2025 [10.1007/978-3-032-10546-2_90].
Advancing Sustainable Climatization by Way of Energy Geostructures in the Retrofitting of Buildings
F. Cecinato;M. Gerola;A. Morcioni;
2026
Abstract
Ground Source Heat Pump systems can significantly contribute to the decarbonization of the built environment but may incur high groundwork costs. Energy Geostructures (EGs) are alternative solutions that combine Heat Pumps with heat exchanger circuits embedded in ground structures, such as foundations and retaining walls, thus reducing installation costs. This paper reviews the state of the art of EGs and the recent advances by the Italian project GEOREFIT, specifically addressing the applicability and efficiency of this technology in energy retrofitting of existing buildings and infrastructures. The paper exemplifies technical solutions for EG installation in refurbishment projects and shows that EG energy performance is generally comparable and sometimes higher than conventional Ground Heat Exchangers.| File | Dimensione | Formato | |
|---|---|---|---|
|
CLIMA_4AIR.pdf
embargo fino al 12/04/2027
Tipologia:
Post-print, accepted manuscript ecc. (versione accettata dall'editore)
Licenza:
Publisher
Dimensione
562.78 kB
Formato
Adobe PDF
|
562.78 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
|
978-3-032-10546-2_90.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Licenza:
Nessuna licenza
Dimensione
3.61 MB
Formato
Adobe PDF
|
3.61 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.