We present an analytical method that allows for the rapid measurement of uranium in water samples. For a 50 ml sample concentrations down to about 2 micro-g/l can be measured within an hour. There are no toxic chemicals used and the whole equipment is portable and can be powered by a 12 V battery. The preparation consists of adding 200 mg silica gel to the 50 ml sample, stirring for 1 hour, filtering out the silica gel and transferring it to a semi-micro cuvette for the measurement. Several samples can be prepared in parallel, depening on the number of magnetic stirrers available. The measurement takes only 1 minute and uses the uranyl fluorescence, enhanced by the adsorption on silica gel. Excitation is done by a pulsed UV-LED at 285 nm. The delayed fluorescence signal around 520 nm is detected by a 6 mm x 6 mm Silicon Photomultiplie (SiPM) behind a 520 nm bandpass filter. Pulsing the LED, converting the SiPM output and displaying the result is controlled by an Arduino microprocessor. All details of the experimental setup as well the software code are presented. It's open source, open to be copied and the whole material costs are only around 500 Euro.
Rapid field measurement of uranium in water samples / K. Hegedűs-Csondor, H.S. - In: EGU General Assembly 2024[s.l] : European Geosciences Union, 2024 Apr. - pp. 1-1 (( EGU General Assembly Wien 2024 [10.5194/egusphere-egu24-12506].
Rapid field measurement of uranium in water samples
P. Baják;
2024
Abstract
We present an analytical method that allows for the rapid measurement of uranium in water samples. For a 50 ml sample concentrations down to about 2 micro-g/l can be measured within an hour. There are no toxic chemicals used and the whole equipment is portable and can be powered by a 12 V battery. The preparation consists of adding 200 mg silica gel to the 50 ml sample, stirring for 1 hour, filtering out the silica gel and transferring it to a semi-micro cuvette for the measurement. Several samples can be prepared in parallel, depening on the number of magnetic stirrers available. The measurement takes only 1 minute and uses the uranyl fluorescence, enhanced by the adsorption on silica gel. Excitation is done by a pulsed UV-LED at 285 nm. The delayed fluorescence signal around 520 nm is detected by a 6 mm x 6 mm Silicon Photomultiplie (SiPM) behind a 520 nm bandpass filter. Pulsing the LED, converting the SiPM output and displaying the result is controlled by an Arduino microprocessor. All details of the experimental setup as well the software code are presented. It's open source, open to be copied and the whole material costs are only around 500 Euro.| File | Dimensione | Formato | |
|---|---|---|---|
|
EGU24-12506-print.pdf
accesso aperto
Tipologia:
Publisher's version/PDF
Licenza:
Creative commons
Dimensione
286.76 kB
Formato
Adobe PDF
|
286.76 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.




