Tidal breathing in awake humans is variable. This variability causes changes in lung gas stores that affect gas exchange measurements. To overcome this, several algorithms provide solutions for breath-by-breath alveolar gas exchange measurement; however, there is no consensus on a physiologically robust method suitable for widespread application. A recent approach, the ‘independent-breath’ (IND) algorithm, avoids the complexity of measuring breath-by-breath changes in lung volume by redefining what is meant by a ‘breath’. Specifically, it defines a single breathing cycle as the time between equal values of the FO2 / FN2 (or FCO2 / FN2) ratio, that is, the ratio of fractional concentrations of lung-expired O2 (or CO2) and nitrogen (N2). These developments imply that the end of one breath is not, by necessity, aligned with the start of the next. Here we demonstrate how the use of the IND algorithm fails to conserve breathby- breath mass balance of O2 and CO2 exchanged between the atmosphere and tissues (and vice versa). We propose a new term, within the IND algorithm, designed to overcome this limitation. We also present the far-reaching implications of using algorithms based on alternative definitions of the breathing cycle, including challenges in measuring and interpreting the respiratory exchange ratio, pulmonary gas exchange efficiency, dead space fraction of the breath, control of breathing, and a broad spectrum of clinically relevant cardiopulmonary exercise testing variables. Therefore, we do not support the widespread adoption of currently available alternative definitions of the breathing cycle as a legitimate solution for breath-by-breath alveolar gas exchange measurement in research or clinical settings.

Breath by breath measurement of alveolar gas exchange must preserve mass balance and conform to a physiological definition of a breath / M. Girardi, C. Capelli, C. Ferguson, S.A. Ward, H.B. Rossiter. - In: EXPERIMENTAL PHYSIOLOGY. - ISSN 0958-0670. - 110:6(2025 Jun 01), pp. 790-797. [10.1113/EP092221]

Breath by breath measurement of alveolar gas exchange must preserve mass balance and conform to a physiological definition of a breath

C. Capelli
Secondo
;
2025

Abstract

Tidal breathing in awake humans is variable. This variability causes changes in lung gas stores that affect gas exchange measurements. To overcome this, several algorithms provide solutions for breath-by-breath alveolar gas exchange measurement; however, there is no consensus on a physiologically robust method suitable for widespread application. A recent approach, the ‘independent-breath’ (IND) algorithm, avoids the complexity of measuring breath-by-breath changes in lung volume by redefining what is meant by a ‘breath’. Specifically, it defines a single breathing cycle as the time between equal values of the FO2 / FN2 (or FCO2 / FN2) ratio, that is, the ratio of fractional concentrations of lung-expired O2 (or CO2) and nitrogen (N2). These developments imply that the end of one breath is not, by necessity, aligned with the start of the next. Here we demonstrate how the use of the IND algorithm fails to conserve breathby- breath mass balance of O2 and CO2 exchanged between the atmosphere and tissues (and vice versa). We propose a new term, within the IND algorithm, designed to overcome this limitation. We also present the far-reaching implications of using algorithms based on alternative definitions of the breathing cycle, including challenges in measuring and interpreting the respiratory exchange ratio, pulmonary gas exchange efficiency, dead space fraction of the breath, control of breathing, and a broad spectrum of clinically relevant cardiopulmonary exercise testing variables. Therefore, we do not support the widespread adoption of currently available alternative definitions of the breathing cycle as a legitimate solution for breath-by-breath alveolar gas exchange measurement in research or clinical settings.
breathing cycle; CPET; gas exchange; kinetics;
Settore BIOS-06/A - Fisiologia
1-giu-2025
22-feb-2025
Article (author)
File in questo prodotto:
File Dimensione Formato  
Experimental Physiology - 2025 - Girardi - Breath‐by‐breath measurement of alveolar gas exchange must preserve mass balance.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Licenza: Creative commons
Dimensione 584.19 kB
Formato Adobe PDF
584.19 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1221325
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
  • OpenAlex 2
social impact