BACKGROUND: Maternal cardiovascular adaptations are amplified in twin pregnancies to support the metabolic request of the feto-placental unit. Few studies have evaluated the maternal hemodynamics changes after routine use of laser surgery in the treatment of twin-twin transfusion syndrome. OBJECTIVE: The aim of our study was to evaluate hemodynamic changes in monochorionic twin pregnancies complicated by twin-twin transfusion syndrome before and after treatment with fetoscopic laser surgery. STUDY DESIGN: A prospective observational study from 2020 to 2022, included monochorionic twin pregnancies complicated with twin-twin transfusion syndrome undergoing laser surgery between 16 and 26 weeks of gestation. To assess placental function and perfusion, uterine artery pulsatility index, hemoglobin, hematocrit, and soluble fms-like tyrosine kinase-1/placental growth factor ratio sampling prelaser and 24 hours postlaser were measured. Echocardiography by a single cardiologist evaluated maternal hemodynamics at presurgery, 24 hours, and 1 week postlaser. Those data were crosswise compared with cardiovascular indices of uncomplicated monochorionic pregnancies recruited at the same gestational age using nonparametric tests. Moreover, we fitted random-intercept linear regression models to investigate maternal hemodynamic changes according to the amount of amniotic fluid drained during laser surgery. RESULTS: Forty-two twin-twin transfusion syndrome pregnancies with a median gestational age of 19.1 (17.4–20.9) weeks and 15 uncomplicated monochorionic pregnancies at the same gestational age were enrolled. Overall survival rate after laser was 72% with delivery at a median gestational age of 31.5 (27–34) weeks. Significant changes in blood chemistry and placental function were observed in the twin-twin transfusion syndrome group, along with alterations in arterial pressure, heart rate, cardiac output, and ventricular strain, eventually aligning with the uncomplicated group's values by 1 week postlaser. The amount of amniodrainage, with a 1000 ml cut-off, did not significantly impact hemodynamic parameters. Lastly, we detected a percentage of laser surgery complications in agreement with international literature and we did not record any maternal procedure-related problems. CONCLUSION: Our analysis highlighted that maternal cardiovascular status in monochorionic twin pregnancy complicated by twin-twin transfusion syndrome was more dynamic and; 1 week after fetoscopic laser ablation of placental anastomosis completed by amniodrainage, maternal hemodynamic parameters restored to values similar to uncomplicated monochorionic twin pregnancies.
Maternal hemodynamic evaluation in monochorionic twin pregnancy complicated by twin-to-twin transfusion syndrome treated with fetoscopic laser surgery / R. Milazzo, M. Garbin, D. Consonni, D. Casati, S. Faiola, A. Laoreti, S. Mannarino, I. Cetin, M.M. Lanna. - In: AMERICAN JOURNAL OF OBSTETRICS & GYNECOLOGY, MATERNAL-FETAL MEDICINE. - ISSN 2589-9333. - 6:3(2024 Mar), pp. 101270.1-101270.9. [10.1016/j.ajogmf.2023.101270]
Maternal hemodynamic evaluation in monochorionic twin pregnancy complicated by twin-to-twin transfusion syndrome treated with fetoscopic laser surgery
R. MilazzoPrimo
;D. Casati;A. Laoreti;I. Cetin;
2024
Abstract
BACKGROUND: Maternal cardiovascular adaptations are amplified in twin pregnancies to support the metabolic request of the feto-placental unit. Few studies have evaluated the maternal hemodynamics changes after routine use of laser surgery in the treatment of twin-twin transfusion syndrome. OBJECTIVE: The aim of our study was to evaluate hemodynamic changes in monochorionic twin pregnancies complicated by twin-twin transfusion syndrome before and after treatment with fetoscopic laser surgery. STUDY DESIGN: A prospective observational study from 2020 to 2022, included monochorionic twin pregnancies complicated with twin-twin transfusion syndrome undergoing laser surgery between 16 and 26 weeks of gestation. To assess placental function and perfusion, uterine artery pulsatility index, hemoglobin, hematocrit, and soluble fms-like tyrosine kinase-1/placental growth factor ratio sampling prelaser and 24 hours postlaser were measured. Echocardiography by a single cardiologist evaluated maternal hemodynamics at presurgery, 24 hours, and 1 week postlaser. Those data were crosswise compared with cardiovascular indices of uncomplicated monochorionic pregnancies recruited at the same gestational age using nonparametric tests. Moreover, we fitted random-intercept linear regression models to investigate maternal hemodynamic changes according to the amount of amniotic fluid drained during laser surgery. RESULTS: Forty-two twin-twin transfusion syndrome pregnancies with a median gestational age of 19.1 (17.4–20.9) weeks and 15 uncomplicated monochorionic pregnancies at the same gestational age were enrolled. Overall survival rate after laser was 72% with delivery at a median gestational age of 31.5 (27–34) weeks. Significant changes in blood chemistry and placental function were observed in the twin-twin transfusion syndrome group, along with alterations in arterial pressure, heart rate, cardiac output, and ventricular strain, eventually aligning with the uncomplicated group's values by 1 week postlaser. The amount of amniodrainage, with a 1000 ml cut-off, did not significantly impact hemodynamic parameters. Lastly, we detected a percentage of laser surgery complications in agreement with international literature and we did not record any maternal procedure-related problems. CONCLUSION: Our analysis highlighted that maternal cardiovascular status in monochorionic twin pregnancy complicated by twin-twin transfusion syndrome was more dynamic and; 1 week after fetoscopic laser ablation of placental anastomosis completed by amniodrainage, maternal hemodynamic parameters restored to values similar to uncomplicated monochorionic twin pregnancies.| File | Dimensione | Formato | |
|---|---|---|---|
|
PIIS2589933323004123_Milazzo-Casati.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Licenza:
Nessuna licenza
Dimensione
297.8 kB
Formato
Adobe PDF
|
297.8 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.




