Introduced as an alternative to open-heart surgery for elderly patients, Transcatheter Aortic Valve Implantation (TAVI) has recently been extended to younger patients due to comparable performance with the gold-standard. However, the long-term durability of the bio-prosthetic TAVI valves is limited by Structural Valve Deterioration (SVD), an inevitable degenerative process whose pathogenesis is still unclear. In this study, we aim to computationally investigate a possible relationship between aortic hemodynamics and SVD development. To this aim, we collect data from twelve patients with and without SVD at long-term follow-up exams. Starting from pre-operative clinical images, we build early post-operative virtual geometries and perform Computational Fluid Dynamics simulations by prescribing a personalized flow rate based on Echo Doppler data. In order to identify a premature onset of SVD, we propose three computational hemodynamic indices: Wall Damage Index (WDI), Leaflet Delamination Index (LDI), and Leaflet Permeability Index (LPI). Additionally, to each index we associate a score and, using the Wilcoxon rank-sum test, we find that each score individually shows a statistically greater median value in the SVD sub-population (WDI: p=0.008, LDI: p=0.001, LPI: p=0.020). Finally, we define a synthetic scoring system that clearly separates between SVD and non-SVD patients. Our results suggest that aortic hemodynamics may drive a premature onset of SVD, and the synthetic score could potentially assist clinicians in a patient-specific planning of follow-up exams to closely monitor those patients at high SVD risk.

Personalized computational hemodynamic analysis in transcatheter aortic valve: investigation of long-term degeneration / L. Crugnola, C. Catalano, L. Fusini, S. Pasta, G. Pontone, C. Vergara. - In: COMPUTERS IN BIOLOGY AND MEDICINE. - ISSN 0010-4825. - 202:(2026), pp. 111435.1-111435.14. [10.1016/j.compbiomed.2025.111435]

Personalized computational hemodynamic analysis in transcatheter aortic valve: investigation of long-term degeneration

C. Catalano;L. Fusini;G. Pontone;C. Vergara
Ultimo
2026

Abstract

Introduced as an alternative to open-heart surgery for elderly patients, Transcatheter Aortic Valve Implantation (TAVI) has recently been extended to younger patients due to comparable performance with the gold-standard. However, the long-term durability of the bio-prosthetic TAVI valves is limited by Structural Valve Deterioration (SVD), an inevitable degenerative process whose pathogenesis is still unclear. In this study, we aim to computationally investigate a possible relationship between aortic hemodynamics and SVD development. To this aim, we collect data from twelve patients with and without SVD at long-term follow-up exams. Starting from pre-operative clinical images, we build early post-operative virtual geometries and perform Computational Fluid Dynamics simulations by prescribing a personalized flow rate based on Echo Doppler data. In order to identify a premature onset of SVD, we propose three computational hemodynamic indices: Wall Damage Index (WDI), Leaflet Delamination Index (LDI), and Leaflet Permeability Index (LPI). Additionally, to each index we associate a score and, using the Wilcoxon rank-sum test, we find that each score individually shows a statistically greater median value in the SVD sub-population (WDI: p=0.008, LDI: p=0.001, LPI: p=0.020). Finally, we define a synthetic scoring system that clearly separates between SVD and non-SVD patients. Our results suggest that aortic hemodynamics may drive a premature onset of SVD, and the synthetic score could potentially assist clinicians in a patient-specific planning of follow-up exams to closely monitor those patients at high SVD risk.
Bio-prosthetic heart valves (BHV); Computational fluid dynamics (CFD); Computational hemodynamic indices; Long-term durability; Patient-specific clinical data; Structural valve deterioration (SVD); Transcatheter aortic valve implantation (TAVI)
Settore MEDS-07/B - Malattie dell'apparato cardiovascolare
2026
Article (author)
File in questo prodotto:
File Dimensione Formato  
personalized.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Licenza: Creative commons
Dimensione 4.22 MB
Formato Adobe PDF
4.22 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1210461
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex 0
social impact