Extracorporeal carbon dioxide removal (ECCO₂R) prevents intubation and facilitates extubation in patients with hypercapnic respiratory failure. However, low-flow systems increase shear stress and need full anticoagulation, increasing the risk of circuit-related complications. We assessed the safety and efficacy of a high-caliber dual-lumen cannula, designed for jugular veno-venous extracorporeal membrane oxygenation (VV ECMO), repurposed for femoral vein insertion, with the aim of achieving higher blood-flow rates and more efficient CO₂ clearance. We retrospectively analyzed 16 intensive care unit (ICU) patients (62 years; 81% chronic obstructive pulmonary disease [COPD]) treated with ECCO₂R using a large-caliber dual-lumen cannula (20-23 Fr) inserted via the femoral vein. Key outcomes included changes in gas exchange, ventilatory support status, and complications. Extracorporeal carbon dioxide removal enabled rapid CO₂ clearance, with arterial carbon dioxide pressure (PaCO₂) decreasing from 68 [62-95] to 49 [45-56] mm Hg at 2 h, and pH increasing from 7.20 [7.16-7.27] to 7.36 [7.33-7.41]. Fifty-six percent of patients avoided intubation, whereas all intubated patients were extubated during ECCO₂R. The median support duration was 5 [4-7] days. No hemolysis was documented. One bleeding episode and one clotting event occurred; no thrombotic or cannulation-related complications were observed. Femoral vein cannulation with a large-caliber dual-lumen cannula for ECCO₂R appears feasible and safe. This strategy may offer technical and clinical advantages over conventional ECCO₂R systems, warranting prospective investigation.

High-Caliber Femoral Dual-Lumen Cannula for ECCO2R in Hypercapnic Respiratory Failure: Efficacy and Safety Evaluation / A. Caccioppola, E. Antonucci, V. Scaravilli, A. Meli, F. Cappelli, A. Lissoni, M. Panigada, G. Grasselli. - In: ASAIO JOURNAL. - ISSN 1058-2916. - (2025). [Epub ahead of print] [10.1097/MAT.0000000000002586]

High-Caliber Femoral Dual-Lumen Cannula for ECCO2R in Hypercapnic Respiratory Failure: Efficacy and Safety Evaluation

E. Antonucci;V. Scaravilli
;
F. Cappelli;G. Grasselli
Ultimo
2025

Abstract

Extracorporeal carbon dioxide removal (ECCO₂R) prevents intubation and facilitates extubation in patients with hypercapnic respiratory failure. However, low-flow systems increase shear stress and need full anticoagulation, increasing the risk of circuit-related complications. We assessed the safety and efficacy of a high-caliber dual-lumen cannula, designed for jugular veno-venous extracorporeal membrane oxygenation (VV ECMO), repurposed for femoral vein insertion, with the aim of achieving higher blood-flow rates and more efficient CO₂ clearance. We retrospectively analyzed 16 intensive care unit (ICU) patients (62 years; 81% chronic obstructive pulmonary disease [COPD]) treated with ECCO₂R using a large-caliber dual-lumen cannula (20-23 Fr) inserted via the femoral vein. Key outcomes included changes in gas exchange, ventilatory support status, and complications. Extracorporeal carbon dioxide removal enabled rapid CO₂ clearance, with arterial carbon dioxide pressure (PaCO₂) decreasing from 68 [62-95] to 49 [45-56] mm Hg at 2 h, and pH increasing from 7.20 [7.16-7.27] to 7.36 [7.33-7.41]. Fifty-six percent of patients avoided intubation, whereas all intubated patients were extubated during ECCO₂R. The median support duration was 5 [4-7] days. No hemolysis was documented. One bleeding episode and one clotting event occurred; no thrombotic or cannulation-related complications were observed. Femoral vein cannulation with a large-caliber dual-lumen cannula for ECCO₂R appears feasible and safe. This strategy may offer technical and clinical advantages over conventional ECCO₂R systems, warranting prospective investigation.
COPD; asthma; dual-lumen; femoral
Settore MEDS-23/A - Anestesiologia
2025
nov-2025
Article (author)
File in questo prodotto:
File Dimensione Formato  
cacioppola_high_caliber_femoral_dual_lumen_cannula_for_ecco2r.839.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Licenza: Creative commons
Dimensione 1.03 MB
Formato Adobe PDF
1.03 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1206530
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact