Importance Most French Olfactory Questionnaires are time consuming, which may affect the patient participation.ObjectiveTo validate a short French version of the Olfactory Disorders Questionnaire (Fr-ODQ).DesignProspective controlled study.SettingMulticenter study.ParticipantsPatients with long-lasting olfactory dysfunction (OD) treated with platelet-rich plasma into the olfactory clefts and asymptomatic subjects.InterventionDevelopment and validation of a short ODQ.Main OutcomesIndividuals completed the full Fr-ODQ. The Threshold, Discrimination, and Identification (TDI) test was performed in OD patients. A combined statistical analysis was performed to determine the most informative items of the Fr-ODQ to develop a shorter version. The internal consistency was determined with Cronbach's alpha. The reliability and external validity were evaluated through a test-retest approach and by correlating with the Fr-ODQ. Both the minimal clinically important difference (MCID) and the threshold of the short ODQ version were determined.ResultsA total of 263 patients (173 [65.8%] females) and 129 controls (92 [71.3%] females) completed the evaluations. The mean age of patients was 51.2 ± 15.3 years. The mean duration of OD was 42.4 ± 54.3 months. The biostatistical models selected 10 essential items composing the Fr-ODQ-10. The baseline Fr-ODQ-10 was significantly correlated with the TDI (rs = 0.228; P = .001) and the Fr-ODQ (rs = 0.875; P = .001), demonstrating high external validity. Fr-ODQ-10 was significantly lower in controls compared to OD patients (P = .001), highlighting high internal validity. The internal consistency was good (α = .796). The external consistency was adequate, with significant correlations between the test-retest Fr-ODQ-10. The Fr-ODQ-10 significantly decreased from baseline to 4 months post-treatment. A Fr-ODQ-10 score >7.5 was considered abnormal (sensitivity: 84.8%, specificity: 84.2%). The MCID of Fr-ODQ-10 was established at >3.Conclusion and RelevanceThe Fr-ODQ-10 is a valid and reliable clinical instrument, demonstrating correlation with the psychophysical olfactory assessment.

Validity and Reliability of the French Olfactory Disorders Questionnaire-10 / J.R. Lechien, L.A. Vaira, L. Lamoulen, L. Sowerby, T. Radulesco, J. Michel, P. Boscolo-Rizzo, G. Salzano, M.R. Barillari, A.M. Saibene, G. Cammaroto, C.M. Chiesa-Estomba, G. Iannella, N. Van Der Poel, K. Sagandykova, S. Saussez, F. Carsuzaa, M. Mayo-Yanez, E.K. Bhargava, A. Maniaci, G. Briganti. - In: JOURNAL OF OTOLARYNGOLOGY-HEAD AND NECK SURGERY. - ISSN 1916-0216. - 54:(2025), pp. 1-10. [10.1177/19160216251387622]

Validity and Reliability of the French Olfactory Disorders Questionnaire-10

A.M. Saibene;
2025

Abstract

Importance Most French Olfactory Questionnaires are time consuming, which may affect the patient participation.ObjectiveTo validate a short French version of the Olfactory Disorders Questionnaire (Fr-ODQ).DesignProspective controlled study.SettingMulticenter study.ParticipantsPatients with long-lasting olfactory dysfunction (OD) treated with platelet-rich plasma into the olfactory clefts and asymptomatic subjects.InterventionDevelopment and validation of a short ODQ.Main OutcomesIndividuals completed the full Fr-ODQ. The Threshold, Discrimination, and Identification (TDI) test was performed in OD patients. A combined statistical analysis was performed to determine the most informative items of the Fr-ODQ to develop a shorter version. The internal consistency was determined with Cronbach's alpha. The reliability and external validity were evaluated through a test-retest approach and by correlating with the Fr-ODQ. Both the minimal clinically important difference (MCID) and the threshold of the short ODQ version were determined.ResultsA total of 263 patients (173 [65.8%] females) and 129 controls (92 [71.3%] females) completed the evaluations. The mean age of patients was 51.2 ± 15.3 years. The mean duration of OD was 42.4 ± 54.3 months. The biostatistical models selected 10 essential items composing the Fr-ODQ-10. The baseline Fr-ODQ-10 was significantly correlated with the TDI (rs = 0.228; P = .001) and the Fr-ODQ (rs = 0.875; P = .001), demonstrating high external validity. Fr-ODQ-10 was significantly lower in controls compared to OD patients (P = .001), highlighting high internal validity. The internal consistency was good (α = .796). The external consistency was adequate, with significant correlations between the test-retest Fr-ODQ-10. The Fr-ODQ-10 significantly decreased from baseline to 4 months post-treatment. A Fr-ODQ-10 score >7.5 was considered abnormal (sensitivity: 84.8%, specificity: 84.2%). The MCID of Fr-ODQ-10 was established at >3.Conclusion and RelevanceThe Fr-ODQ-10 is a valid and reliable clinical instrument, demonstrating correlation with the psychophysical olfactory assessment.
Olfactory Disorder Questionnaire; anosmia; odor; olfaction; otolaryngology; rhinology; smell
Settore MEDS-18/A - Otorinolaringoiatria
2025
Article (author)
File in questo prodotto:
File Dimensione Formato  
validity-and-reliability-of-the-french-olfactory-disorders-questionnaire-10 (2025).pdf

accesso aperto

Tipologia: Publisher's version/PDF
Licenza: Creative commons
Dimensione 1.31 MB
Formato Adobe PDF
1.31 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1199716
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact