Objective: Until now, only way to report air leaks (ALs) has been with an analogue score in an inherently subjective manner. The Six Sigma quality improvement methodology is a data-driven approach applicable to evaluate the quality of the quantification method of repetitive procedures. We applied the Six Sigma concept to improve the process of AL evaluation. Methods: A digital device for AL measurement (Drentech PALM, Redax S.r.l., Mirandola (MO), Italy) was applied to 49 consecutive patients, who underwent pulmonary intervention, compared with a similar population with classical chest drainage. Data recorded were postoperative AL, chest-tube removal days, number of chest roentgenograms, hospital length of stay; device setup time, average time rating AL and patient satisfaction. Bivariable comparisons were made using the Mann-Whitney test, the χ 2 test and Fisher's exact test. Analysis of quality was conducted using the Six Sigma methodology. Results: There were no significant differences regarding AL (p=0.075), although not statistically significant; there was a reduction of postoperative chest X-rays (four vs five) and of hospital length of stay (6.5 vs 7.1 days); and a marginally significant difference was found between chest-tube removal days (p=0.056). There were significant differences regarding device setup time (p=0.001), average time rating AL (p=0.001), inter-observer variability (p=0.001) and patient satisfaction (p=0.002). Six Sigma analyses revealed accurate assessment of AL. Conclusions: Continuous digital measurement of AL reduces degree of variability of AL score, gives more assurance for tube removal, and reports AL without the apprehension of observer error. Efficiency and effectiveness improved with the use of a digital device. We have noted that the AL curves depict actually sealing of AL. The clinical importance of AL curves requires further study.
Six sigma approach - an objective strategy in digital assessment of postoperative air leaks: a prospective randomised study / L. Bertolaccini, G. Rizzardi, M. Filice, A. Terzi. - In: EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY. - ISSN 1010-7940. - 39:5(2011 May), pp. E128-E132. [10.1016/j.ejcts.2010.12.027]
Six sigma approach - an objective strategy in digital assessment of postoperative air leaks: a prospective randomised study
L. Bertolaccini
Primo
;
2011
Abstract
Objective: Until now, only way to report air leaks (ALs) has been with an analogue score in an inherently subjective manner. The Six Sigma quality improvement methodology is a data-driven approach applicable to evaluate the quality of the quantification method of repetitive procedures. We applied the Six Sigma concept to improve the process of AL evaluation. Methods: A digital device for AL measurement (Drentech PALM, Redax S.r.l., Mirandola (MO), Italy) was applied to 49 consecutive patients, who underwent pulmonary intervention, compared with a similar population with classical chest drainage. Data recorded were postoperative AL, chest-tube removal days, number of chest roentgenograms, hospital length of stay; device setup time, average time rating AL and patient satisfaction. Bivariable comparisons were made using the Mann-Whitney test, the χ 2 test and Fisher's exact test. Analysis of quality was conducted using the Six Sigma methodology. Results: There were no significant differences regarding AL (p=0.075), although not statistically significant; there was a reduction of postoperative chest X-rays (four vs five) and of hospital length of stay (6.5 vs 7.1 days); and a marginally significant difference was found between chest-tube removal days (p=0.056). There were significant differences regarding device setup time (p=0.001), average time rating AL (p=0.001), inter-observer variability (p=0.001) and patient satisfaction (p=0.002). Six Sigma analyses revealed accurate assessment of AL. Conclusions: Continuous digital measurement of AL reduces degree of variability of AL score, gives more assurance for tube removal, and reports AL without the apprehension of observer error. Efficiency and effectiveness improved with the use of a digital device. We have noted that the AL curves depict actually sealing of AL. The clinical importance of AL curves requires further study.| File | Dimensione | Formato | |
|---|---|---|---|
|
39-5-e128.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Licenza:
Nessuna licenza
Dimensione
209.82 kB
Formato
Adobe PDF
|
209.82 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.