Background: The accurate assessment of resting energy expenditure (REE) is essential for personalized nutrition, particularly in critically ill children. Indirect calorimetry (IC) is the gold standard for measuring REE. This methodology is based on the measurement of oxygen consumption (VO2) and carbon dioxide production (VCO2). These parameters are integrated into the Weir equation to calculate REE. Additionally, IC facilitates the determination of the respiratory quotient (RQ), offering valuable insights into a patient's carbohydrate and lipid consumption. IC validation is limited to spontaneously breathing and mechanically ventilated patients, but it is not validated in patients undergoing non-invasive ventilation (NIV). This study investigates the application of IC during NIV-CPAP (continuous positive airway pressure) and NIV-PS (pressure support). Methods: This study was conducted in the Pediatric Intensive Care Unit of IRCCS Ca' Granda, Ospedale Maggiore Policlinico, Milan, between 2019 and 2021. Children < 6 years weaning from NIV were enrolled. IC was performed during spontaneous breathing (SB), NIV-CPAP, and NIV-PS in each patient. A Bland-Altman analysis was employed to compare REE, VO2, VCO2, and RQ measured by IC. Results: Fourteen patients (median age 7 (4; 18) months, median weight 7.7 (5.5; 9.7) kg) were enrolled. The REE, VO2, VCO2, and RQ did not differ significantly between the groups. The Limits of Agreement (LoA) and bias of REE indicated good agreement between SB and NIV-CPAP (LoA +28.2, -19.4 kcal/kg/day; bias +4.4 kcal/kg/day), and between SB and NIV-PS (LoA -22.2, +23.1 kcal/kg/day; bias 0.4 kcal/kg/day). Conclusions: These preliminary findings support the accuracy of IC in children undergoing NIV. Further validation in a larger cohort is warranted.

Validation of Indirect Calorimetry in Children Undergoing Single-Limb Non-Invasive Ventilation: A Proof of Concept, Cross-Over Study / V. D'Oria, G.C.I. Spolidoro, C.V. Agostoni, C. Montani, L. Ughi, C. Villa, T. Marchesi, G. Babini, S. Scalia Catenacci, G. Donà, M. Guerrini, G. Chidini, E. Calderini, T. Langer. - In: NUTRIENTS. - ISSN 2072-6643. - 16:2(2024), pp. 230.1-230.12. [10.3390/nu16020230]

Validation of Indirect Calorimetry in Children Undergoing Single-Limb Non-Invasive Ventilation: A Proof of Concept, Cross-Over Study

G.C.I. Spolidoro
Secondo
;
C.V. Agostoni
;
C. Villa;T. Marchesi;G. Babini;E. Calderini;T. Langer
2024

Abstract

Background: The accurate assessment of resting energy expenditure (REE) is essential for personalized nutrition, particularly in critically ill children. Indirect calorimetry (IC) is the gold standard for measuring REE. This methodology is based on the measurement of oxygen consumption (VO2) and carbon dioxide production (VCO2). These parameters are integrated into the Weir equation to calculate REE. Additionally, IC facilitates the determination of the respiratory quotient (RQ), offering valuable insights into a patient's carbohydrate and lipid consumption. IC validation is limited to spontaneously breathing and mechanically ventilated patients, but it is not validated in patients undergoing non-invasive ventilation (NIV). This study investigates the application of IC during NIV-CPAP (continuous positive airway pressure) and NIV-PS (pressure support). Methods: This study was conducted in the Pediatric Intensive Care Unit of IRCCS Ca' Granda, Ospedale Maggiore Policlinico, Milan, between 2019 and 2021. Children < 6 years weaning from NIV were enrolled. IC was performed during spontaneous breathing (SB), NIV-CPAP, and NIV-PS in each patient. A Bland-Altman analysis was employed to compare REE, VO2, VCO2, and RQ measured by IC. Results: Fourteen patients (median age 7 (4; 18) months, median weight 7.7 (5.5; 9.7) kg) were enrolled. The REE, VO2, VCO2, and RQ did not differ significantly between the groups. The Limits of Agreement (LoA) and bias of REE indicated good agreement between SB and NIV-CPAP (LoA +28.2, -19.4 kcal/kg/day; bias +4.4 kcal/kg/day), and between SB and NIV-PS (LoA -22.2, +23.1 kcal/kg/day; bias 0.4 kcal/kg/day). Conclusions: These preliminary findings support the accuracy of IC in children undergoing NIV. Further validation in a larger cohort is warranted.
critically ill children; indirect calorimetry; non-invasive ventilation; pediatric intensive care; resting energy expenditure
Settore MEDS-20/A - Pediatria generale e specialistica
Settore MEDS-23/A - Anestesiologia
Settore MEDS-08/C - Scienza dell'alimentazione e delle tecniche dietetiche applicate
2024
Article (author)
File in questo prodotto:
File Dimensione Formato  
nutrients-16-00230.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Licenza: Creative commons
Dimensione 2.03 MB
Formato Adobe PDF
2.03 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1189600
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
  • OpenAlex 1
social impact