Purpose: To predict the normalized glandular dose (DgN) coefficients and the related uncertainty in mammography and digital breast tomosynthesis (DBT) using a machine learning algorithm and patient-like digital breast models. Methodology: 126 patient-like digital breast phantoms were used for DgN Monte Carlo ground truth calculations. An Automatic Relevance Determination Regression algorithm was used to predict DgN from anatomical breast features. These features included compressed breast thickness, glandular fraction by volume, glandular volume, center of mass and standard deviation of the glandular tissue distribution in the cranio-caudal direction. An algorithm for data imputation was explored to account for avoiding the use of the latter two features. Results: 5-fold cross validation showed that the predictive model provides an estimation of DgN with 1% average difference from the ground truth; this difference was less than 3% in 50% of the cases. The average uncertainty of the estimated DgN values was 9%. Excluding the information related to the glandular distribution increased this uncertainty to 17% without inducing a significant discrepancy in estimated DgN values, with half of the predicted cases differing from the ground truth by less than 9%. The data imputation algorithm reduced the estimated uncertainty, without restoring the original performance. Predictive performance improved by increasing tube voltage. Conclusion: The proposed methodology predicts the DgN in mammography and DBT for patient-derived breasts with an uncertainty below 9%. Predicting test evaluations reported 1% average difference from the ground truth, with 50% of the cohort cases differing by less than 5%.
Uncertainty and normalized glandular dose evaluations in digital mammography and digital breast tomosynthesis with a machine learning methodology / A. Sarno, R.T. Massera, G. Paternò, P. Cardarelli, N. Marshall, H. Bosmans, K. Bliznakova. - In: PHYSICA MEDICA. - ISSN 1724-191X. - 136:(2025 Jul 08), pp. 105043.1-105043.10. [10.1016/j.ejmp.2025.105043]
Uncertainty and normalized glandular dose evaluations in digital mammography and digital breast tomosynthesis with a machine learning methodology
A. SarnoPrimo
;
2025
Abstract
Purpose: To predict the normalized glandular dose (DgN) coefficients and the related uncertainty in mammography and digital breast tomosynthesis (DBT) using a machine learning algorithm and patient-like digital breast models. Methodology: 126 patient-like digital breast phantoms were used for DgN Monte Carlo ground truth calculations. An Automatic Relevance Determination Regression algorithm was used to predict DgN from anatomical breast features. These features included compressed breast thickness, glandular fraction by volume, glandular volume, center of mass and standard deviation of the glandular tissue distribution in the cranio-caudal direction. An algorithm for data imputation was explored to account for avoiding the use of the latter two features. Results: 5-fold cross validation showed that the predictive model provides an estimation of DgN with 1% average difference from the ground truth; this difference was less than 3% in 50% of the cases. The average uncertainty of the estimated DgN values was 9%. Excluding the information related to the glandular distribution increased this uncertainty to 17% without inducing a significant discrepancy in estimated DgN values, with half of the predicted cases differing from the ground truth by less than 9%. The data imputation algorithm reduced the estimated uncertainty, without restoring the original performance. Predictive performance improved by increasing tube voltage. Conclusion: The proposed methodology predicts the DgN in mammography and DBT for patient-derived breasts with an uncertainty below 9%. Predicting test evaluations reported 1% average difference from the ground truth, with 50% of the cohort cases differing by less than 5%.| File | Dimensione | Formato | |
|---|---|---|---|
|
1-s2.0-S112017972500153X-main.pdf
accesso riservato
Tipologia:
Publisher's version/PDF
Licenza:
Nessuna licenza
Dimensione
1.57 MB
Formato
Adobe PDF
|
1.57 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.