Background: Contouring of anatomical regions is a crucial step in the medical workflow and is both time-consuming and prone to intra- and inter-observer variability. This study compares different strategies for automatic segmentation of the prostate in T2-weighted MRIs. Methods: This study included 100 patients diagnosed with prostate adenocarcinoma who had undergone multi-parametric MRI and prostatectomy. From the T2-weighted MR images, ground truth segmentation masks were established by consensus from two expert radiologists. The prostate was then automatically contoured with six different methods: (1) a multi-atlas algorithm, (2) a proprietary algorithm in the Syngo.Via medical imaging software, and four deep learning models: (3) a V-net trained from scratch, (4) a pre-trained 2D U-net, (5) a GAN extension of the 2D U-net, and (6) a segmentation-adapted EfficientDet architecture. The resulting segmentations were compared and scored against the ground truth masks with one 70/30 and one 50/50 train/test data split. We also analyzed the association between segmentation performance and clinical variables. Results: The best performing method was the adapted EfficientDet (model 6), achieving a mean Dice coefficient of 0.914, a mean absolute volume difference of 5.9%, a mean surface distance (MSD) of 1.93 pixels, and a mean 95th percentile Hausdorff distance of 3.77 pixels. The deep learning models were less prone to serious errors (0.854 minimum Dice and 4.02 maximum MSD), and no significant relationship was found between segmentation performance and clinical variables. Conclusions: Deep learning-based segmentation techniques can consistently achieve Dice coefficients of 0.9 or above with as few as 50 training patients, regardless of architectural archetype. The atlas-based and Syngo.via methods found in commercial clinical software performed significantly worse (0.855- 0.887 Dice).

Comparison of automated segmentation techniques for magnetic resonance images of the prostate / L.J. Isaksson, M. Pepa, P. Summers, M. Zaffaroni, M.G. Vincini, G. Corrao, G.C. Mazzola, M. Rotondi, G. Lo Presti, S. Raimondi, S. Gandini, S. Volpe, Z. Haron, S. Alessi, P. Pricolo, F.A. Mistretta, S. Luzzago, F. Cattani, G. Musi, O.D. Cobelli, M. Cremonesi, R. Orecchia, G. Marvaso, G. Petralia, B.A. Jereczek-Fossa. - In: BMC MEDICAL IMAGING. - ISSN 1471-2342. - 23:1(2023 Feb 11), pp. 32.1-32.16. [10.1186/s12880-023-00974-y]

Comparison of automated segmentation techniques for magnetic resonance images of the prostate

L.J. Isaksson
Primo
;
M. Pepa
Secondo
;
G.C. Mazzola;M. Rotondi;S. Gandini;S. Volpe;P. Pricolo;F.A. Mistretta;S. Luzzago;G. Musi;R. Orecchia;G. Marvaso;G. Petralia
Penultimo
;
B.A. Jereczek-Fossa
Ultimo
2023

Abstract

Background: Contouring of anatomical regions is a crucial step in the medical workflow and is both time-consuming and prone to intra- and inter-observer variability. This study compares different strategies for automatic segmentation of the prostate in T2-weighted MRIs. Methods: This study included 100 patients diagnosed with prostate adenocarcinoma who had undergone multi-parametric MRI and prostatectomy. From the T2-weighted MR images, ground truth segmentation masks were established by consensus from two expert radiologists. The prostate was then automatically contoured with six different methods: (1) a multi-atlas algorithm, (2) a proprietary algorithm in the Syngo.Via medical imaging software, and four deep learning models: (3) a V-net trained from scratch, (4) a pre-trained 2D U-net, (5) a GAN extension of the 2D U-net, and (6) a segmentation-adapted EfficientDet architecture. The resulting segmentations were compared and scored against the ground truth masks with one 70/30 and one 50/50 train/test data split. We also analyzed the association between segmentation performance and clinical variables. Results: The best performing method was the adapted EfficientDet (model 6), achieving a mean Dice coefficient of 0.914, a mean absolute volume difference of 5.9%, a mean surface distance (MSD) of 1.93 pixels, and a mean 95th percentile Hausdorff distance of 3.77 pixels. The deep learning models were less prone to serious errors (0.854 minimum Dice and 4.02 maximum MSD), and no significant relationship was found between segmentation performance and clinical variables. Conclusions: Deep learning-based segmentation techniques can consistently achieve Dice coefficients of 0.9 or above with as few as 50 training patients, regardless of architectural archetype. The atlas-based and Syngo.via methods found in commercial clinical software performed significantly worse (0.855- 0.887 Dice).
Deep learning; Medical image; MRI; Prostate; Segmentation;
Settore MEDS-22/A - Diagnostica per immagini e radioterapia
11-feb-2023
Article (author)
File in questo prodotto:
File Dimensione Formato  
unpaywall-bitstream-2130771803.pdf

accesso aperto

Tipologia: Publisher's version/PDF
Licenza: Creative commons
Dimensione 2.77 MB
Formato Adobe PDF
2.77 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2434/1173783
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 10
  • OpenAlex ND
social impact